CC112X/CC1175
SWRU295C
Page 92 of 108
FS_DIG0
Bit no.
Name
Reset
R/W Description
7:4
FS_DIG0_RESERVED7_4
0x05
R/W For test purposes only, use values from SmartRF Studio
3:2
RX_LPF_BW
0x02
R/W FS loop bandwidth in RX
00
101.6 kHz
01
131.7 kHz
10
150 kHz
11
170.8 kHz
1:0
TX_LPF_BW
0x02
R/W FS loop bandwidth in TX
00
101.6 kHz
01
131.7 kHz
10
150.0 kHz
11
170.8 kHz
FS_CAL3
Bit no. Name
Reset
R/W Description
7:5
FS_CAL3_NOT_USED
0x00
R
4
KVCO_HIGH_RES_CFG
0x00
R/W KVCO High Resolution Enable
0
High resolution disabled (normal resolution mode)
1
High resolution enabled (increased charge pump calibration, but will extend
the calibration time)
3:0
FS_CAL3_RESERVED3_0
0x00
R/W For test purposes only, use values from SmartRF Studio
FS_CAL2
Bit no. Name
Reset
R/W Description
7:6
FS_CAL2_NOT_USED
0x00
R
5:0
VCDAC_START
0x20
R/W VCDAC start value. Use value from SmartRF Studio
FS_CAL1
Bit no. Name
Reset
R/W Description
7:0
FS_CAL1_RESERVED7_0
0x00
R/W For test purposes only, use values from SmartRF Studio
FS_CAL0
Bit no. Name
Reset
R/W Description
7:4
FS_CAL0_NOT_USED
0x00
R
3:2
LOCK_CFG
0x00
R/W Out of lock detector average time
00
Average the measurement over 512 cycles
01
Average the measurement over 1024 cycles
10
Average the measurement over 256 cycles
11
Infinite average
1:0
FS_CAL0_RESERVED1_0
0x00
R/W For test purposes only, use values from SmartRF Studio
FS_CHP - Charge Pump Configuration
Bit no. Name
Reset
R/W Description
7:6
FS_CHP_NOT_USED
0x00
R
5:0
CHP_CAL_CURR
0x28
R/W Charge Pump Current and Calibration. Use values from SmartRF Studio
FS_DIVTWO - Divide by 2
Bit no. Name
Reset
R/W Description
7:2
FS_DIVTWO_NOT_USED
0x00
R
1:0
FS_DIVTWO_RESERVED1_0
0x01
R/W For test purposes only, use values from SmartRF Studio