Automatic boiler for wood pellets
27
Picture No. 22 Required chimney draft
Chimney systems resistant to humidity in which condensation of water vapour is permitted are recommended in
order to ensure long-term trouble-free and safe operation of the boiler. (Chimneys resistant to humidity are
recommended for appliances with temperature of combustion products from 30°C to 100°C.)
4.1.3
Fire regulations
ČSN 73 0823 / 1984 – fire and technical properties and combustibility grades
ČSN 06 1008 / 1997 – fire safety of heat installations, structure of boilers from fire safety aspect
4.1.4
Electrical
Government Regulation no.17/2003 Coll.
ČSN – EN 60 335-1 ed.2.20073– Electrical appliances for domestic and other similar use – Safety - General
requirements.
ČSN – EN 60 335-2-102:2007- Safety – Part 2-102: Special requirements for appliences burning gas, petroleum
and solid fuels containing electrical connections.
4.1.5
Protection against noise
Government Regulation no. 148/2006 Coll. – product is fullfilling all requirements.
5.4
STORAGE OF FUEL
Wood pellets have to be in a dry place protected against atmospheric effects because humidity damages the and
aggravates their burning parameters. Excessive humidity completely destroys pellets. They should be stored in a
different room than the boiler or at least 1,500 mm from the boiler.
Operating stock of fuel may be stored in a special central bin which has to be manufactured from non-
combustible material. Bins supplied by the manufacturer meet operating and safety requirements. They may be
filled without any limits up to their total volume.
Large-volume bins have to meet corresponding fire and safety regulations. The supplier is obliged to work out
working regulations and instructions for operation and maintenance of large-volume bins.
5.5
BOILER ROOM VENTILATION
Permanent ventilation of the boiler within approximately 75 m
3
x hour
-1
of fresh air has to be ensured, if a boiler
of approximately 20 kW of power output is operated.
Summary of Contents for KP 12-ES
Page 21: ...Automatic boiler for wood pellets 20 Picture No 15 Jacketing KP 22S KP 22 ES ...
Page 22: ...Automatic boiler for wood pellets 21 Picture No 16 Jacketing KP 62S KP 62 ES ...
Page 43: ...Automatic boiler for wood pellets 42 9 3 1 2Menu users settings ...
Page 45: ...Automatic boiler for wood pellets 44 Cleaning an ash removeing Skin Time window setting ...
Page 48: ...Automatic boiler for wood pellets 47 Actual values Configuration ...
Page 54: ...Automatic boiler for wood pellets 53 Cleaning Ash removing USB Time window setting ...
Page 55: ...Automatic boiler for wood pellets 54 Load from USB Save on USB ...
Page 60: ...Automatic boiler for wood pellets 59 ...
Page 62: ...Automatic boiler for wood pellets 61 ...
Page 63: ...Automatic boiler for wood pellets 62 i ...
Page 70: ...69 Picture No 31 Principle of the modulation ...
Page 72: ...71 Picture No 33 Directory information consuption wood pellets for boiler family KP ...
Page 73: ...72 Picture No 34 Circuit diagram control unit ...
Page 74: ...73 Picture No 35 Circuit diagram modul HZS 533 ...
Page 75: ...74 Picture No 36 Circuit diagram HZS 533 HZS 535 ...