Information contained in this manual relates exclusively to the TERA system component specified on the 

title page. New versions and modifications may be developed without prior notice to current users. TESLA 
has made every attempt to provide you with complete, error-free and accurate information in this manual. 
TESLA is not liable for errors or omissions contained in this document, or for any damages however resulted 
from using or relying on any information contained herein. TESLA's liability for errors shall be strictly limited 
to correcting such errors and providing advisory services as described below. 

Users should be familiar with operation basis of used product. If you experience any problems with your 

product, please contact us at: 

 

TESLA 

Rubeska 215/1 

190 00 Prague 9 - Vysocany 

www.tesla.cz

 

 

1

 

Introduction 

This document describes technical specifications and user operation of TPS2 Power Relay.  

The product was developed and manufactured in the Czech Republic. All rights reserved TESLA. Offer or 

delivery of products or services related to the product does not include transfer of ownership rights. 

Before  using  the  product,  please  read  this  manual  carefully  and  understand  all  operating  and  safety 
precautions. Compliance with operational and safety precaution can prevent from damage to equipment or 
injuries to personnel. Operating and safety instructions in the document are marked as follows: 

Attention! 

 

This formatted text indicates the operating and safety instructions. 

The product may only be used in the specified manner and for its intended purpose. The product may be 

provided to third persons along with this documentation only. 

 

2

 

Description and Utilization  

Power element is basically made up of high power switching which is controlled by the Actuator output 

or  the  Central  Unit  output.  Actuator  and  Central  Unit  are  parts  of  TERA  program  made  by  TESLA;  see 

http://www.tesla.cz/

 and 

http://www.tesla.cz/

  This connection is by cable 

 contacts of actuator (central) 

memory relay switch voltage on power relay coil. Power relay

 

is mostly located near an actuating unit (fan, 

recuperation unit, etc.). By a switch on box of power relay it is possible to choose permanent switching of 
relay 

 

position ´ON´ 

or  choose switching of relay by automatic control signal 

 position 

´

AUT

´

TPS2 Power Relay can be used in this system: 

TERA System for Radon Concentrations Regulating (Figure 1)  

 

Regulating  system  diagram  description

  -  Radon  measuring  probes  located  in  building  transmit  their 

current radon concentration values to central unit wirelessly. Central unit analyzes this information and on 
the  basis  of  measured  (set)  concentration  level  value  it  sends  wireless  command  to  actuator  which  is 
hardwired with power relay. Power relay switches on a fan which decreases  radon concentration within an 
area. After decreasing of radon concentration, actuator receives a command to switch off the fan. This cycle 
repeats depending on increasing or decreasing volume activity of radon in  building. 