MODEL WM-IIRO-8

USER MANUAL

Summary of Contents for WM-IIRO-8

Page 1: ...1 10623 Roselle Street San Diego CA 92121 C 858 550 9559 C Fax 858 550 7322 info accesio com C www accesio com MODEL WM IIRO 8 USER MANUAL...

Page 2: ...CES nor the rights of others IBM PC PC XT and PC AT are registered trademarks of the International Business Machines Corporation Printed in USA Copyright 2005 by ACCES I O Products Inc 10623 Roselle S...

Page 3: ...parts not excluded by warranty W arranty com mences with equipment shipment Following Years Throughout your equipment s lifetime ACCES stands ready to provide on site or in plant service at reasonabl...

Page 4: ...ion 5 Figure 1 1 Block Diagram 6 Chapter 2 Installation 7 Chapter 3 Option Selection 8 Figure 3 1 Option Selection Map 8 Table 3 1 WM IIRO 8 Screw Terminal Connections 9 Chapter 4 Software 11 General...

Page 5: ...nge is 3 to 28 volts rms Unused power dissipates through a 1 8KS resistor External resistors connected in series with this may be used to extend the input voltage range Each input circuit contains a s...

Page 6: ...6 Manual W M IIRO 8 Figure 1 1 Block Diagram...

Page 7: ...mputer s COM Ports The COM Port selected MUST be configured for the following settings Protocol RS232 Baud Rate 9600 Data Bits 7 Parity Even Stop Bits 1 VERIFY INSTALLATION 1 Locate and run ACCES WINR...

Page 8: ...hannel basis W hen jumper FLT0 is installed additional filtering is introduced for input bit 0 FLT1 for bit 1 etc This additional filtering must be used when AC inputs are applied JUMPER SELECTION Bit...

Page 9: ...lay 4 common 12 Isolated Input 7 A 12 Relay 4 normally open 13 Isolated Input 6 B 13 N C 14 Isolated Input 6 A 14 N C 15 Isolated Input 5 B 15 Relay 3 normally closed 16 Isolated Input 5 A 16 Relay 3...

Page 10: ...oltage can be anywhere from 7 5 VDC to 16 VDC Higher local power 24 VDC for example can be used if an external zener diode is used to reduce the voltage applied to RIOD24 See Temperature de rating com...

Page 11: ...ode Addressed Mode The address select comm and must be issued before any other command to the addressed pod The address command is as follows xx CR where xx is the pod address from 01 to FF hex and C...

Page 12: ...xx Set digital input active state high or low on bit xx CR Cxx Read digital input xx counter counts each active pulse xxCR or Read pulse free run output xx counter and reload value xxCR Rxx Reset digi...

Page 13: ...or time xx bx xx Identical to Ox xx bxx xx Identical to Oxx xx These comm ands write outputs to digital bits Any attempt to write to a bit configured as input will fail W riting to a byte or word wher...

Page 14: ...bit mask to enable change of state to set the COS flag on the pod for readback by the Y or address comm ands If a one is set for a particular bit that bit will set the COS flag if when the bit changes...

Page 15: ...s since last reset Reset Counter rxx Reset digital input counter xx This command is normally used to reset a digital input counter to zero Examples Reset digital input counter for digital input number...

Page 16: ...ramming Pod Address A xx Program the currently selected pod to respond at address xx This com mand changes the pod s address to xx If the new address is 00 the pod will be placed into non addressed mo...

Page 17: ...rial port Data can be resent by issuing a D comm and This will dump the last stored historical data to the serial port and can be used for example if line noise or similar problems are suspected This...

Page 18: ...arity error This occurs when some part of the received data contains a parity or framing error Additionally several full text error codes are returned All begin with Error and are useful when using a...

Page 19: ...e 7 5 to 15 volts Current Range 130 mA idle mode 30 mA increase per relay activation 100 mA increase during constant transmission 470 mA maximum Idle mode may be reduced to 70 mA with cyclic sleep mod...

Page 20: ...Current 1 A Max Switching Voltage 125 VAC 60 VDC Max Switching Capacity 62 5 VA 30 W Contact Resistance 100 mS max Operate Time 5 ms Release Time 5 ms Contact Life mechanical 5 million operations Envi...

Page 21: ...example at an ambient temperature of 25 C the voltage VI can be up to 15 9V At an ambient temperature of 100 F 37 8 C the voltage VI can be up to 14V Storage Temperature Range 20 C to 70 C Hum idity 5...

Page 22: ...st want to give us some feedback please email us at manuals accesio com Please detail any errors you find and include your mailing address so that we can send you any manual updates 10623 Roselle Stre...