43
ENG
Mounting plate
Wall-through Hole
Route of Pipeline
1. The wall for installation of the indoor unit shall be hard and
firm, so as to prevent vibration.
2. Use the “+” type screw to fasten the peg board, horizontally
mount the peg board on the wall, and ensure the lateral
horizontal and longitudinal vertical.
3. Pull the peg board by hand after the installation, to confirm
whether it is solid.
1. Make a hole with an electric hammer or a water drill at the
predetermined position on the wall for piping, which shall
slant outwardly by 5° -10° .
2. To protect the piping and the cables from being damaged
running through the wall, and from the rodents that may
inhabit in the hollow wall, a pipe protecting ring shall be
installed and sealed with putty.
Note
: Usually, the wall hole is
ɸ
60mm~
ɸ
80mm. Avoid pre-
buried power wire and hard wall when making the hole.
1. Depending on the position of the unit, the piping may be routed sideway from the left or the right (Fig 1), or
vertically from the back (Fig 2) (depending on the pipe length of the indoor unit). In the case of sideway routing,
cut off the outlet cutting stock of the opposite side.
Pipe protection
ring
Connecting Pipe
Drain Hose and
Cables
Connecting Pipe
Drain Hose and
Cables
Outlet material preparation
Fig 2
Putty
Fig 1
Summary of Contents for TA22FFML-07410A
Page 59: ......
Page 60: ...www tesla info ...