54
ENG
4. The recovered refrigerant shall be loaded in the appropriate storage tanks, attached with a transporting
instruction, and returned to the refrigerant manufacturer. Don’t mix refrigerant in recovery equipment, especially
a storage tank.
5. The space loading R32 refrigeration can’t be enclosed in the process of transportation. Take anti electrostatic
measures if necessary in transportation. In the process of transport, loading and unloading, necessary protective
measures must be taken to protect the air conditioner to ensure that the air conditioner is not damaged.
6. When removing the compressor or clearing the compressor oil, make sure the compressor is pumped to an
appropriate level to ensure that there is no residual R32 refrigerants in the lubricating oil. The vacuum pumping
should be carried out before the compressor is returned to the supplier. Ensure the safety when discharging oil
from the system.
REMOTE CONTROLLER INSTRUCTIONS
Attention
• Read this “instructions” carefully so that you can use the air-conditioner safely and correctly.
• Take good care of the “instructions” so that it can be referred to at any time.
1. Aim the remote controller towards the receiver on the airconditioner.
2. The remote controller should be within 8 meters away from the receiver.
3. No obstacles between the remote controller and receiver.
4. Do not drop or throw the remote controller.
5. Do not put the remote controller under the forceful sun rays or heating facilities and other heating sources.
6. Use two 7# batteries, do not use the electric batteries.
7. Take the batteries out of remote controller before stop its using for long.
8. When the noise of transmitting signal can’t be heard indoor unit or the transmission symbol on the display
screen doesn’t flare, batteries need be replaced.
9. If reset phenomenon occurs on pressing the button of the remote controller, the electric quantity is deficient
and new batteries need to be substituted.
10. The waste battery should be disposed properly.
Note
:
• The picture is general remote controller, contains almost all of the function buttons. They may be slightly
different from material abject(depend on model).
• All the figures above are the displays after being initially electrified or re-electrified after power off. In actual
operations, the remote controller screen displays related items only.
• The cooling only units don’t have the function of heating or electric heating. When the remote controller turns to
such function buttons, the units will not result such effect. Please don’t turn the remote controller to such buttons.
Summary of Contents for TA22FFML-07410A
Page 59: ......
Page 60: ...www tesla info ...