POWER SUPPLY OPTIONS
For basic operation, Wall Connector requires an electrical connection to Line 1, Neutral, and Protective Earth
(PE) terminals. Connection to Line 2 and Line 3 terminals is supported for some grid types.
CAUTION:
Wall Connector supports 230 V L-N (+/- 10%). Mis-wiring the neutral terminal with >264V to
PE can damage Wall connector
Wall Connector can operate on a three-phase power supply or a single-phase power supply.
Table 1. Most Common Installation Option
Wiring Configuration Option for Five Wires: Line 1, Line 2, Line 3, Neutral, PE
Grid type options:
• 400 V 3-phase wye
CAUTION:
Double check N connection
is 230 V L to N at terminals of wirebox
before energizing.
NOTE:
Blue is used as the IEC standard for neutral. Some markets may use other colors to symbolize neutral
and line conductors.
6
Gen 3 Wall Connector Manual