Disconnect mains power after setting.
⚫
The LCD display screen will automatically extinguish in about 1 min, and the
setting will be configured normally.
5.4 UPS Settings
⚫
Output voltage setting
LCD display
Settings
For 208/220/230/240 VAC models, you may choose the
following output voltage:
208:
output voltage is 208Vac
220:
output voltage is 220Vac
230
(default)
:
output voltage is 230Vac
240:
output voltage is 240Vac
⚫
Low voltage of battery setting
LCD display
Settings
The battery voltage selecting interface. You may choose the
following output voltage:
9.8:
Low voltage of battery is 9.8Vdc
9.9:
Low voltage of battery is 9.9Vdc
10:
Low voltage of battery is 10Vdc
10.2:
Low voltage of battery is 10.2Vdc
10.5:
Low voltage of battery is 10.5Vdc
dEF
(default)
:
EOD voltage automatically varies with loads,
including 20 hours discharge protection
⚫
Bypass mode setting
LCD display
Settings
Enable or disable Bypass function. You may choose the
following two options:
ON:
Bypass enable
OFF
(default)
:
Bypass disable
⚫
AUO setting