TMS-UT-0114-T01-1
NOTE:
If the room thermostat is on, check if it is set at the necessary room temperature and if supply
batteries are in order, otherwise the boiler will not operate.
5.5. Working with electronic control panels (option E)
Part n umb er: 1659
4
0
2
bar
52
12
11
1
2
3
4
5
6
0
I
7
Electronic control panel without external temperature compensation
1.
Multipurpose – temperature indicator (temperature of boiler,
adjustment of temperature)
2.
Indication of operation degree of heaters (1., 2., 3.....7)
3.
Signalization of air appearance in the boiler (red light)
4.
Signalization of under voltage protection (red light)
5.
Signalization of boiler operation (green light)
6.
Adjustment of temperature in boiler
7.
Switch for central heating switching on and off
8.
Thermal fuse
Putting on central heating
By switching the switch (7) to the position 1, the central heating system is switched on. Upon switching
on, a desired water temperature in boiler is displayed for 5 seconds, signalization of boiler operation is
twinkling (5). Upon 5 seconds real temperature in the boiler is displayed (1); if the current temperature
in boiler meets the desired one, the signalization lamp of boiler operation (5) is switched off.
Adjustment of desired temperature of central heating
By pressing the key for temperature adjustment (6) the desired temperature in the boiler appears, the
signalization lamp of boiler operation (5) is twinkling. By repeated pressing upwards or downwards it is
possible to increase or decrease the desired sanitary water temperature. When the temperature is
adjusted it is sufficient to wait for 5 seconds (signalization lamp of boiler operation (5) does not twinkle)
in order for the boiler to memorizes a new temperature.
Air in the boiler (3), red light
If the air appears in the boiler, the signalization of air in the boiler turns on (3) and the boiler operation
stops. In this way the boiler is protected against malfunction caused by the appearance of air. For the
continuation of operation, the boiler should be vented. If the boiler is correctly vented, the operation of
boiler continues automatically.
Voltage drop (4), red light
If the voltage in the network line drops below 180V by phase, the signalization of under voltage
protection (4) turns on, the boiler automatically switches off in order to protect the electronics and