>5 sec
0
-1
>5 sec
>10 sec
>5 sec
20
32
>5 sec
<5 sec
>15 sec
1.4
Display of external temperature
By pressing the key (6) user can see external temperature.
The Display shows the external temperature. The value is displayed for 5 s, after
which the display normally shows the real temperature of water in the boiler.
Offset of currently selected correction curve
By pressing the key (6) user can enter the curve selection menu.
The LED display will show current offset in
˚C. Offset does not affect maximal or
minimal temperature, they are set in absolute values
By pressing the key (6) it is possible to change
offset in steps of 1˚C.
Factory setting is 0˚C.
Offset range is from –
9 to +20˚C.
If the key is held pressed less than 5 s the displayed value becomes valid offset
in ˚C.
Setting the minimal temperature inside the boiler
By pressing the key (6) user can select minimal temperature inside the boiler.
Minimal temperature starts blinking.
Factory setting is 27°C for radiator heating.
Factory setting is 20°C for under floor heating.
By pressing the key user can select the desired temperature in range from 10 to
50°C. Temperature changes in steps of 1°C. If the key is held pressed less than
5 s the value from the display becomes the desired minimal boiler temperature.
Displaying software version and factory reset
By pressing the key (6) longer than 15 seconds, the LED will show the software
version and the factory reset of central heating parameters will occur.