>5 sec
1.0
36
>5 sec
>10 sec
>5 sec
20
32
>5 sec
<5 sec
>15 sec
1.4
Display of current temperature in domestic water storage
By pressing the key (8) user can select the display of current temperature in the
domestic water storage. The value is displayed for 5 s, after which the display
normally shows the real temperature of water in the boiler.
Setting additional working time of domestic water pump
By pressing the key (8) user can setup additional working time of domestic water
pump.
The time of supplemental operation of circulation pump operation for domestic
water conditioning is blinking.
By pressing the key the time is changing from 0,1 min up to 19 min. with the step
of 1 digit. If the key is held pressed less than 5 s, the value from a display
becomes valid time of supplemental operation of circulation pump for domestic
warm water conditioning.
Factory setting is 1 min.
Setting stand by temperature inside boiler
By pressing the key (8) user can setup stand by temperature inside the boiler.
The LED will show current standby temperature inside the boiler.
Pressing the key (8) will change standby temperature in range from 10°C to
50°C by 1°C. If the key is held pressed less than 5 s the value from the display
becomes the valid standby temperature inside the boiler.
Displaying software version and factory reset
By pressing
the key (8) longer than 15 seconds, the LED will show the software
version and the factory reset of central heating parameters will occur.