Parallel operation of central heating and sanitary
water
When both modes of operation are active, central
heating and sanitary water preparation, the boiler
prefers sanitary water.
If there is a requirement for warm water, the boiler
starts with preparation of sanitary water, the lamp (10)
turns on, whereas the boiler operation signalization
turns off (5); temperature indicator (1) displays the
current temperature of warm water outlet.
Air in the boiler (3), red light
If in the boiler the air appears, the signalization of air
in the boiler turns on (3) and the boiler stops the
operation. In this way the boiler is protected against
blowing because of appearance of air. For
continuation of operation, the boiler should be vented.
If the boiler is correctly vented, the operation of boiler
continues automatically.
Voltage drop (4), red light
If the voltage in the network line drops below 180V by
phase, the signalization of under voltage protection (4)
turns on, the boiler automatically switches off in order
to protect electronics and contactors inside the boiler.
The boiler shall automatically continue the operation
when the network voltage reaches values above
180V.
Thermal fuse - turning on
By means of thermal fuse (12) the boiler is protected
against rapid increase of temperature above 115°C.
The fuse turns off the boiler and ejects the FID-switch.
For continuation of operation it is necessary to take off
the protection cover from the thermal fuse and press
the red key, upon which the FID-switch should be
switched on again.
Segment of the control panel
Segment of the control panel