2.2.2. Technical data
Parameter
Unit
SYSTEM BOILER: ECOCONDENS SILVER PLUS
COMBI BOILER: ECOCONDENS SILVER PLUS
-20
-25
-35
-20
-25
-35
Size
E n e r g e t i c p a r a m e t e r s
C e n t r a l h e a t i n g c i r c u i t
Boiler thermal power at 80/60
o
C (modulated)
kW
2.7 ÷ 20.0
3.9 ÷ 24.0
4.1 ÷ 34.7
2.7 ÷ 20.0
3.9 ÷ 24.0
4.1 ÷ 34.7
Boiler thermal power at 50/30
o
C (modulated)
kW
3.0 ÷ 22.0
4.3 ÷ 26.5
4.5 ÷38.2
3.0 ÷ 22.0
4.3 ÷ 26.5
4.5 ÷ 38.2
Heat load
kW
2.8 ÷ 20.4
4.0 ÷ 24.6
4.2 ÷ 35.6
2.8 ÷ 20.4
4.0 ÷ 24.6
4.2 ÷ 35.6
The efficiency of the boiler at nominal load
and average boiler water temp. 70
o
C
%
97.6
98.0
98.0
97.6
98.0
98.0
The efficiency of the boiler at partial load and
return water temperature 30
o
C
%
107.9
108.7
109.0
107.9
108.7
109.0
Modulation range
%
13-100
16-100
12-100
13-100
16-100
12-100
Seasonal space heating energy
efficiency
ɳ
s
%
91
92
92
91
92
92
Seasonal space heating energy efficiency
class
A
Useful heat output :
- at rated heat output
P
4
- at 30% of rated heat output
P
1
kW
kW
20.0
6.0
24.0
7.2
34.7
10.4
20.0
6.0
24.0
7.2
34.7
10.4
Useful efficiency :
-
ɳ
4
-
ɳ
1
%
88.0
97.0
87.9
96.9
87.8
96.5
88.0
97.0
87.9
96.9
87.8
96.5
Nominal kinetic pressure in front of the boiler
for gas:
2E-G20, 2H-G20
3B/P-G30, 3P-G31
Pa (mbar)
2000 (20); 2500 (25); 2000 (20); 1300 (13)
2800 ÷ 3000 (28 ÷ 30); 3000 (30); 3700 (37); 5000 (50)
Maximum water pressure
MPa (bar)
0,3 (3)
Max temperature (central heating)
o
C
95
Standard adjustable temperature
Reduced adjustable temperature
°C
40 ÷ 80
25 ÷ 55
Lift of the pump at flow 0
kPa (bar)
70 (0,7)
70 (0,7)
D o m e s t i c h o t w a t e r c i r c u i t
Nominal heat output of the boiler
at temp. 80/60
o
C
kW
-----
2.7 ÷ 25
3.9 ÷ 30.0
4.1 ÷ 40.0
Nominal heat load
kW
-----
2.8 ÷ 25.6
4.0 ÷ 30.7
4.2 ÷ 41.0
The efficiency of the boiler at nominal load
and average boiler water temperature of
70°C
%
-----
97.6
98.0
98.0
Water heating energy efficiency class
A
A
A
Load profile
L
XL
XL
Water pressure
MPa (bar)
-----
0.01 (0.1)
÷
0.6 (6)
Min water flow
l/min
-----
2.0
Max water flow (flow limiter)
dm
3
/min
-----
-----
-----
----
Range of water temperature regulation
°C
30 - 60
Flow of domestic water for
∆
t=30K
dm
3
/min
12
14
19
E n v i r o n m e n t a l p r o t e c t i o n
Emissions of nitrogen oxides
mg/kWh
21
24
29
21
24
29
Emission of NO
x
(natural gas)
class
5
The pH of the condensate
natural gas - 5
Sound power level L
WA
dB
48
48
48
48
48
48
H y d r a u l i c p a r a m e t e r s
Expansion vessel capacity
dm
3
6
Water pressure in expansion vessel
MPa (bar)
0.08
±0.02
(0.8
±0.2
)
E l e c t r i c p a r a m e t e r s
Type and supply voltage
V
~ 230 ±10%/ 50Hz
Degree of protection
IP44
Power consumption
W
110
Standby mode power consumption P
SB
kW
0.005
Electricity consumption :
- at full load el
max
- at part load el
min
kW
kW
0.05
0.02
0.05
0.02
0.05
0.02
0.05
0.02
0.05
0.02
0.05
0.02
Maximum nominal current value of output
terminals
A
2
Controller classification according to PN EN
298
F-M-C-L-X-K
Type of flame sensor
ionization
T h e p a r a m e t e r s o f f l u e g a s
Fan characteristics
section 4.4 of this manual
Flue gas mass flow at full load
kg/h
51.4
72.3
90.4
51.4
72.3
90.4
Flue gas mass flow at partial load
kg/h
5.4
9.5
9.6
5.4
9.5
9.6
The minimum flue gas temperature at
minimum thermal power
°
C
44
34.3
34.3
44
34.3
34.3
The maximum flue gas temperature at
maximum thermal power
°
C
61
66.9
66.7
61
66.9
66.7
T i m e p a r a m e t e r s
Time of central heating pump rundown
s
180
Time preventing the anti-cyclical startup of
the boiler (Anti-cycling time)
minutes
3-60
Time of domestic hot water pump rundown
s
20-180
Protection against pump and valve blocking
h /s
the pump turns on for 180 seconds every 24 hours
the pump and three way valve turns on for 15 seconds every 48 hours