ECOCONDENS SILVER  PLUS                                                                                                   

ISU-646:2016/GR-H                                                                                        str.26 

 

 

Combi boiler 

 

No 

Description 

No 

Description 

No 

Description 

No 

Description 

User interface 

(foil) 

10 

Ignition/Flame control 

electrode 

26 

D.H.W. flow sensor / 

Tank time regulator 

54 

Connector "In System 
Programming"- 
microprocessor programming 

User interface  

(control board) 

15 

Heating water 

temperature limiter 

27 

NTC sensor of D.H.W. 

temperature  

P1 

Button OFF / RESET 

Fan 

16 

Fumes temperature 

limiter 

41 

Room temperature 

regulator 

P2 

Buttons SET 

Pump 

18 

NTC sensor of  heating 

water temperature 

42 

NTC sensor of outside 

temperature 

P3 

 

Gas unit 

20 

Heating water pressure 

sensor 5V 

44 

Fuse 

P4 

Button - 

Flame control 

electrode 

24 

Heating water flow 

sensor 

51 

3-way valve 

CM 

Blockade of extended mode of 

control system configuration 

M3 

Connector 

coupling PE 

M5 

Flame control connector 

JKEY 

User interface  

connector (foil) 

ROP 

Pump speed regulator 

TWN 

Spark generator 

NTCP 

NTC sensor of heating 

water temperature 

(return) 

M13 

User interface connector 

ROV 

Fan speed regulator 

Fig.6.2.1. Schematic diagram of the electrical connections 

6.3. The maintenance operations to be performed by the user  
User should: 

 

clean the water filter periodically, preferably before the heating season (should be replaced when used), 

 

clean the domestic water filter also in case of  finding decreasing flow, 

 

refill the central heating system with the water, 

 

deaerate the central heating system and the boiler, 

 

periodically clean the boiler cover with the water with detergent (avoid cleaners that cause scratches). 

 

6.4. Range of technical maintenance performed by service company 

 

Maintenance of the combustion chamber, burner, ignition electrode and ionization electrode  

 

Cleaning the condensate siphon 

 

The pressure in the expansion tank 

 

Maintenance of the water-water heat exchanger  

 

Check the temperature sensors (

 table) 

 

Replacing a damaged control boar in the control panel 

 

Checking the water pump operation according section. 6.1.6. 

  

7. BOILER EQUIPMENT 

In table 7.1 there is placed a list of parts required for installation of the boiler, its proper operation and for enhancement the comfort of 
usage of the product. The following items are available for purchase together with the boiler or are supplied with the boiler.

 

 
 

Summary of Contents for ECOCONDENS SILVER PLUS-20

Page 1: ...COMBI BOILERS SYSTEM BOILERS ECOCONDENS SIL VER PLUS 20 ECOCONDENS SIL VER PLUS 25 ECOCONDENS SIL VER PLUS 35 ECOCONDENS SIL VER PLUS 20 ECOCONDENS SIL VER PLUS 25 ECOCONDENS SIL VER PLUS 35 1450...

Page 2: ...system Filters are not included in a basic boiler equipment An example of connecting a boiler to these systems is presented on fig 3 5 1 All defects caused by lack of filters on central heating or gas...

Page 3: ...ing on the boiler s type Shut off the filling valve after reaching the pressure of 1 0 1 5 bar Note in some models of boilers after end of the start procedure the support the venting of boiler functio...

Page 4: ...ction of a room temperature regulator 15 3 10 CONNECTING THE OUTSIDE TEMPERATURE SENSOR 15 4 BOILER ADJUSTMENT AND PRELIMINARY SETTING 15 4 1 INTRODUCTORY REMARKS 15 4 2 ADJUSTING THE BOILER TO COMBUS...

Page 5: ...tallation B23 Further information regarding the type according section 3 8 and PN EN 15502 2 1 2013 04 2 BOILER DESCRIPTION 2 1 Technical specification 2 1 1 Technical features 2 2 Design and technica...

Page 6: ...on of elements in system boiler ECOCONDENS SILVER PLUS Only Fig 2 2 1 3 1 Swich of boiler function selection 2 Temperature selector c h or d h w 3 Heating water domestic water and static pressure temp...

Page 7: ...e boiler at nominal load and average boiler water temperature of 70 C 97 6 98 0 98 0 Water heating energy efficiency class A A A Load profile L XL XL Water pressure MPa bar 0 01 0 1 0 6 6 Min water fl...

Page 8: ...power supply of the three way valve item 12 towards the central heating installation pump supply item 7 fan supply item 5 the sequence of ignition then the driver starts the fan speed regulation so as...

Page 9: ...C Domestic water temperature on the inlet t 5 C Fig 2 4 3 2 Diagram of domestic water temperature at the boiler outlet at thermal power of 30kW depending on the water flow rate 9 50 15 0 10 5 25 30 20...

Page 10: ...es the pump according to For conventional PWM pump operation parameter P 15 0 PWM Pump activation by parameter P12 works with a modulated speed in C H system activating by signal from RT room temperat...

Page 11: ...should be protected against freezing free from dust and aggressive gases It is forbidden to install the device in a laundry rooms drying rooms and in varnish cleaners solvents and sprays storages Boi...

Page 12: ...the wall Hang the boiler on hooks fastened durably in the wall using a beam placed in upper part of the boiler The boiler shall be so located as to permit the eventual repair without any need to disma...

Page 13: ...e device its parameters and components life After boiler installation Fill the heating system with water by filling valve item 22 Fig 2 2 1 1 for combi boiler For system boiler install filling valve f...

Page 14: ...ulations some types of installations might not be allowed Always consult your local regulations before making flue gas system project Before turning on the boiler check if flue gas system is made acco...

Page 15: ...ER PLUS 35 Maximum length of chimney flue Lmax 20m L max 60 100 80 125 or coaxial reduction O60 100 x O80 125 Coaxial elbow 90 O60 100 Coaxial elbow 90 O80 125 3 8 3 Vertical outlet of air flue gas sy...

Page 16: ...er index T9000 00 54 00 sealing the connection with a gasket In place of flue gas outlet after the dismantling of the coaxial adapter 60 100 and reducing ring 60 80 the adapter should be screwed index...

Page 17: ...10 Connecting the outside temperature sensor To connect the outside temperature sensor use the 2 wire cable 2x0 5mm 2 50m max and connect it to terminals 3 and 4 AFS located under the right flap Fig 3...

Page 18: ...gas flow rate on the gas meter for compliance with Table 4 3 2 1 If you need to change the gas flow turn the screw pos 6 Fig 4 2 1 Turn the screw to the left to increase the flow turn the screw to th...

Page 19: ...99 P03 77 P02 99 P03 87 P02 99 The content of CO2 in the flue gas The content of CO2 in the flue gas 11 0 0 5 11 0 0 5 Gas flow rate l min Gas flow rate l min 3P G31 37 1 8 0 5 2 6 0 5 2 8 0 5 13 4 1...

Page 20: ...heating Service function Anti legionella function active only for boilers with tanks SUMMER Press button for about 1 second changing the operating mode to mode SUMMER D H W heating Anti legionella fu...

Page 21: ...to support venting of the heating system It consists of successive six cycles switching on the pump for 15 sec and switching off the pump for 15 sec alternately in CH and DHW circuit Lock of heating...

Page 22: ...ding on boiler type Parameter is visible when the CM clamp is removed P07 Type of CH circuit 1 closed 1 Boiler adapted for closed central heating system P08 Type of heating 0 1 0 standard heating 1 fl...

Page 23: ...ND BY section 5 3 In such conditions the controller of the boiler has a protective function described in point 5 3 Performed functions If You decide to discontinue use of the boiler for a long time yo...

Page 24: ...thermal fuse was burned off and the boiler was switched off with blockade Call Authorized Service Company Damage in the circuit of NTC sensor of heating water temperature The burner is turned off Call...

Page 25: ...ld be replaced Note Dirty burner and the interior of the combustion chamber mean that the boiler regulation must be done In order to get into the combustion chamber burner and electrode close the gas...

Page 26: ...panel Measure the sensor resistance Temperature C NTC DHW and NTC CH sensor resistance NTC tank sensor and temperature sensor resistance Sensor 3977 10 55218 0 75 0 32624 0 75 10 19897 0 75 20 12 480...

Page 27: ...x 230V AC 7 Pump Yonos Para PWM Power 45W 230V AC 8 Gas unit SIT SIGMA 848 Valve coil resistance 3 4 EV1 0 9 k 1 3 EV2 6 4 k 230V AC 18 NTC sensor of CH water temperature 10K 25 C 3977 SELV 19 Heating...

Page 28: ...lator Fig 6 2 1 Schematic diagram of the electrical connections 6 3 The maintenance operations to be performed by the user User should clean the water filter periodically preferably before the heating...

Page 29: ...ion 60 100 x 80 125 T9000016700 1 Elements of the system according to the installation design 1 set Flue gas air system coaxial 60 100 Fig 3 8 2 1 4 Coaxial elbow 60 100 90 with revision T9000015 300...

Page 30: ...nstallation design 1 set Flue gas air system coaxial 60 100 Fig 3 8 3 1 6 Coaxial inspection T piece T9000007200 1 ECOCONDENS SILVER PLUS Not included in boiler equipment Elements of the system accord...

Page 31: ......

Reviews: