ECOCONDENS SILVER PLUS
ISU-646:2016/GR-H str.14
Table 3.8.4.1.
2
m in 140
min 140
H
1
m
in
1
4
0
O60
xxx
210
H
O60
or appropriately O80
or appropriately O80
Dimensions
of the chimney duct
Type of boiler
Coaxial system
∅
60/
∅
100
ECOCONDENS SILVER PLUS -20
Maximum length of chimney flue
L
max
=15 m
ECOCONDENS SILVER PLUS -25
Maximum length of chimney flue
L
max
=17 m
ECOCONDENS SILVER PLUS -35
Maximum length of chimney flue
L
max
=12 m
Type of boiler
Coaxial system
∅
80/
∅
125
ECOCONDENS SILVER PLUS -20
Maximum length of chimney flue
L
max
=25 m
ECOCONDENS SILVER PLUS -25
Maximum length of chimney flue
L
max
=25 m
ECOCONDENS SILVER PLUS -35
Maximum length of chimney flue
L
max
=20 m
3.8.5. Flue gas air outlet and air inlet by two separate tubes
To apply the steel two-pipe system should:
•
Unscrew the top cover of the combustion chamber at point of connection of the air supply system to the boiler
•
Retain a gasket existing under the cover
•
In place of the removed cover screw the adapter (index T9000.00.54.00) sealing the connection with a gasket,
•
In place of flue gas outlet after the dismantling of the coaxial adapter
∅
60/
∅
100 and reducing ring
∅
60/
∅
80 the adapter should be
screwed (index T9000.01.11.00). Bottom part of the adapter should be inserted in the boiler flue gas outlet and the connection
should be sealed by the gasket attached to the adapter
To apply the polypropylene two-pipe system should:
•
Unscrew the top cover of the combustion chamber at point of connection of the air supply system to the boiler
•
Disassemble coaxial adapter
∅
60/
∅
100 and reducing ring
∅
60/
∅
80
•
Mount adapter set (index T9000.02.10.00)
Notice: The horizontal air tube should be mounted at an angle of ~ 3° (
Figure 3.8.5.1) so that rain water that gets into the pipes
would not flood the boiler and flowed outside the building.
Table 3.8.5.1.
8
0
1
H
2
80
H
Air
Elements of steel air-flue gas pipes
Fumes
Type of boiler
Separate system
∅
80 x
∅
80
ECOCONDENS SILVER PLUS -20 Maximum length of chimney
flue H
1
+ H
2
L
max
=25 + 25 = 50 m
ECOCONDENS SILVER PLUS -25 Maximum length of chimney
flue H
1
+ H
2
L
max
=25 + 25 = 50 m
ECOCONDENS SILVER PLUS -35 Maximum length of chimney
flue H
1
+ H
2
L
max
=20 + 20 = 40 m