ECOCONDENS SILVER PLUS
ISU-646:2016/GR-H str.18
•
Check the pump (
item.6.1.6),
•
Connect the boiler to the electrical mains,
•
Open the gas valve and water valves,
•
Turn on controller by using an electric switch, available at the bottom of the boiler through a hole in the bottom tray
(
Fig. 2.2.1.1 and 3.9.1)
•
Wait until the boilers enters auto-diagnosis mode.
•
Set the mode WINTER or SUMMER (
item.5.3)
The turning on of the boiler in the heating season
•
Set the desired temperature of the heating water using buttons:{+ / - CH} in the range of 40°C to 80°C
•
The spark generator will cause ignition of gas outflowing from the burner.
•
Set the desired water temperature using buttons (
pos.6) in the range of 30°C to 60°C.
Remember! The priority is always to obtain domestic hot water during operation of the boiler
When the room temperature controller is connected, set desired room temperature on the controller.
5.3. Operating modes of the controller
Mode
Display
Changing the operating mode
Performed functions
STAND-
BY
To turn on /turn off the controller
press the RESET button for
about 2 seconds
•
anti-freezing function: the boiler is
switched on when the boiler
water temp. drops below 8°C and
heats
the water as long as the
temperature reaches 20°C
•
protection against pump blocking
(pump is switched on 180 sec
every 24 hours)
•
3-way valve blocking protection
(valve is switched on 15sec.
every 48 hours)
WINTER
Press button
for about 1 second -
changing the operating mode
to mode WINTER
•
CH and DHW heating,
•
Service function,
•
Anti-legionella function - active
only for boilers with tanks
SUMMER
Press button
for about 1 second -
changing the operating mode to
mode SUMMER
•
D.H.W. heating,
•
Anti-legionella function - active
only for boilers with tanks,
5.4. Signalization of operation states and diagnosis
When the controller starts the operation after power loss (restart) the display shows a flashing symbol . The symbol disappears if the
control system will be ready to accept user commands.
Symbol
on the
display
Signalization
Remarks
BURNER IS OPERATING
Left flame: DHW mode operation.
Right flame: CH mode operation.
WEATHER FUNCTION
IS ACTIVE
During the CH setting changing, instead of the temperature the value of Kt parameter
is displayed
for example: 5.2 without symbol: °C.
CHANGING C.H. SETTING
During changing the CH setting symbol flashes with the set value.
CHANGING DHW SETTING
During changing the DHW temperature setting symbol flashes with the set
value.
MAX
MAXIMUM SETTINGS
Maximum setting value is reached. If you exit the setting changes mode the symbol is
blanked.
MIN
MINIMUM SETTINGS
Minimum setting value is reached. If you exit the setting changes mode the symbol is
blanked.
L3
PAUSE IN C.H. HEATING
Displayed L3 symbol means a pause in C.H. heating in time determined by parameter
P25 (default 3 min) for heat exchanger cooling when C.H. temperature exceedes the
hysteresis value (parameter P20, default 5°C) of th e setting. Pump operation will be
stopped if the following conditions are met:
•
no signal „HEAT” from room temperature regulator,
•
heating water temperature dropped by 5°C from the the set value
•
180 sec. have passed after burner switching off.
reset
reset
reset