S-40 XC, S-45 XC, S-40 TRAX, S-45 TRAX
The range of motion light is on
when the platform load exceeds
660 lbs/300 kg.
Light on indicates restricted range
of motion due to platform weight.
The range of motion light is on
when the platform load is less than
660 lbs/300 kg and on a slope
Light on indicates restricted range
of motion due to platform weight
and slope angle.
Note: When the Machine On
Incline indicator light is on and the
tilt alarm sounds, the following
functions are affected; drive and
lift up functions are disabled.
Follow the Operator Envelope
Indicator Lights procedure to
restore drive and lift functions.
LCD Screen
The LCD screen at the ground controls displays
hour meter, voltage, oil pressure and coolant
temperature. The screen also displays fault codes
and other service information.
Contact Alarm (if equipped)
The contact alarm is designed to alert ground
personnel when an operator makes contact with
the platform control panel, interrupting boom
movement, sounding an alarm and flashing
warning lights.
When the contact alarm cable is tripped, the lift
and drive functions are disabled at the platform.
The audio and visual warnings will activate alerting
others that assistance may be needed. These
notifications will continue until the system is reset.
1 The contact alarm cable is tripped, releasing
the actuator from the switch socket.
2 Insert the actuator into the switch socket to
turn off flashing lights and audio alarm.
a actuator
b contact alarm cable
c flashing alarm
d switch socket
Summary of Contents for Genie S-40 HF