First Edition • Third Printing
Operator's Manual
Inspections
Part No. 1274724GT
S
®
-40/45 XC
™
• S
®
-40/45
HF • S
®
-40/45 TRAX
™
37
Pre-operation Inspection
Be sure that the operator’s, safety, and
responsibilities manuals are complete, legible
and in the storage container located in the
platform.
Be sure that all decals are legible and in place.
See Inspections section.
Check for hydraulic oil leaks and proper oil
level. Add oil if needed. See Maintenance
section.
Check for battery fluid leaks and proper fluid
level. Add distilled water if needed. See
Maintenance section.
Check for engine oil leaks and proper oil level.
Add oil if needed. See Maintenance section.
Check for engine coolant leaks and proper
level of coolant. Add coolant if needed. See
Maintenance section.
Check air-filled tires for proper tire pressure.
Add air if needed. See Maintenance section.
Check the following components or areas for
damage, improperly installed, or missing parts and
unauthorized modifications:
Electrical components, wiring, and
electrical cables
Hydraulic hoses, fittings, cylinders, and
manifolds
Fuel and hydraulic tanks
Drive and turntable motors and drive hubs
Wear pads
Tires and wheels
Engine and related components
Limit switches and horn
Contact alarm
Primary boom angle sensor
Turntable level sensor
String pot length sensor
Alarms and beacons (if equipped)
Nuts, bolts and other fasteners
Platform entry mid-rail and gate
Platform load cell
Lanyard anchorage points