Work Ar ea Safety
Electrocution Hazards
Pictures in this manual may show a boom with
tires and wheels instead of tracks. All safety
information and operating instructions still apply to
the S-40 TRAX and the S-45 TRAX, even if the
picture does not show the tracks.
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Obey all local and
governmental regulations
regarding required
clearance from electrical
power lines. At a minimum,
the required clearance
contained in the chart
below must be followed.
Line Voltage
Required Clearance
0 to 50KV
10 ft
3.05 m
50 to 200KV
15 ft
4.60 m
200 to 350KV
20 ft
6.10 m
350 to 500KV
25 ft
7.62 m
500 to 750KV
35 ft
10.67 m
750 to 1000KV
45 ft
13.72 m
Allow for platform movement, electrical line sway
or sag, and beware of strong or gusty winds.
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must
not touch or operate the
machine until energized
power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity for the
restricted or unrestricted range of motion.
S-40/45 XC and S-40/45 TRAX
Maximum platform capacity
Unrestricted range of motion
660 lbs 300 kg
S-40/45 HF
Maximum platform capacity
Unrestricted range of motion
600 lbs 272 kg
Maximum occupants
2
S-40/45 XC and S-40/45 TRAX
Maximum platform capacity
Restricted range of motion
1,000 lbs 454 kg
Maximum occupants
3