C-33
Document 57.0007.0200 - 01/2006
OPERATING INSTRUCTIONS
Handler with telescopic boom
GTH-4013
■
C-5.2.3 Alarm codes and resetting
The limiter has diagnostic facilities to aid in the
identification of failures of the transducers, breakages
of the cables or defects of the electronic system.
When a failure is signalled, the limiter enters the safety
mode blocking any dangerous manoeuvres. Lights
5
,
8
and
10
start flashing, the buzzer start sounding and
an error message is shown on the display.
The meaning of the error messages is shown in Section
E
“
Faults and
Troubleshooting”
.
DANGER
Before using the machine, make sure that the first
green LED of the overload warning system is ON.
The overload warning system must not be used to
check the load going to be lifted: it has only been
designed to signal possible unbalances of the
machine along its motion axis.
Such unbalances may also be caused by an abrupt
operation of the levers during the load handling. If,
during work, several indicators light up, operate the
levers more smoothly.