Page
E-2
Document 57.0007.0200 - 01/2006
FAULTS AND TROUBLESHOOTING
Handler with telescopic boom
GTH-4013
E-1 FAULTS AND TROUBLESHOOTING
DANGER
Any repair work, maintenance or troubleshooting
must be carried out with machine stopped, boom
in rest position or laid on the ground, parking brake
engaged and ignition key removed.
This chapter represents a practical guide for the
operator for fixing the most common failures and, at
the same time, detecting those interventions that must
be carried out by qualified technical engineers.
If you are unsure about anything, do not carry out
operations on the machine, but call in a skilled
technician.
■
E-1.1 Fault - Cause - Solution
THE DASHBOARD DOES NOT TURN
ON
THE ENGINE DOES NOT START
The starter does not run
THE ENGINE DOES NOT START
The starter runs, but the engine
does not start
THE MACHINE DOES NOT MOVE
FORWARD/BACK
• Battery disconnected
• Battery down
• Fuse in the engine compartment box
blown (
F2G
)
• Forward/reverse gear selector not in
neutral position
• Battery down
• Battery cut-out switch ON
• Emergency button ON
• Engine start fuse blown (
F5G
)
• No fuel
• Fuel filter clogged
• Fuel hose empty (fuel used up)
• Changeover switch in neutral
• Mechanical gear not engaged
• Parking brake engaged
• Fuse
F14
blown
• Outrigger micro-switches ON
• Connect the battery using the
relevant switch
• Check the battery condition
• Check the main fuse in the engine
compartment and replace if
necessary
• Set the switch to
0
• Recharge or replace the battery
• Disconnect the battery
• Reset the button
• Check the engine starting fuse
located in the box in the engine
compartment and replace if
necessary.
• Refuel.
• Change the filter. See engine
operator handbook
• Refuel, then refer to engine operator
handbook
• Set the gear switch to correct
position
• Engage the gear
• Disengage
• Check the 10A fuse
F14
and replace
if necessary.
• Check that the mechanical limit
stops are in the rest position
PROBLEM
CAUSES
SOLUTIONS
Summary of Contents for Genie GTH-4013
Page 2: ......