Page
D-32
Document 57.0007.0200 - 01/2006
MAINTENANCE
Handler with telescopic boom
GTH-4013
■
D-5.2.4
Grease
For the machine greasing, use:
■
D-5.2.3
Fuel
Refuel through cap
A
. Use only Diesel fuel with less
than 0.5% sulphur content, according to the
specifications of the diesel engine operation handbook.
ATTENTION
In cold climates (temperature under -20
°
C) use only
“Arctic” type Diesel fuel, or oil-diesel fuel, or oil-
diesel fuel mixtures. The composition of the latter
can vary in relation to the ambient temperature up
to max. 80% oil.
ATTENTION
Avoid mixing greases of different type or features
and do not use greases of lower quality.
■
D-5.2.5
Engine coolant
It is advisable to use an antifreeze mixture (50% water-
50% antifreeze). At the delivery, the machine is refilled
with:
TEREX PRO COOL by VALVOLINE
The use of this product guarantees protection to the
circuit for 3 years or 7000 hours without having to add
any dry coolant additive.
TEREX PRO COOL
Protection against boiling / freezing
Product
Freezing
Boiling
%
point
point
33
-17
°
C
123
°
C
40
-24
°
C
126
°
C
50
-36
°
C
128
°
C
70
-67
°
C
135
°
C
ATTENTION
Use an antifreeze mixture in the proportions
recommended by the manufacturer in relation to
the ambient temperature of the jobsite.
When greasing by pump
When greasing by brush
For the telescopic boom
sliding blocks
• Lithium-based
Vanguard LIKO
grease, type EP2
• Graphitized AGIP
grease, type GR NG 3
• INTERFLON FIN
GREASE LS 2