Page
D-24
Document 57.0007.0200 - 01/2006
MAINTENANCE
Handler with telescopic boom
GTH-4013
P
■
Checking the limit switches of the outriggers
(at
every use)
To check the limit switches of the outriggers:
•
Lower the outriggers to the ground and attempt to
engage a gear.
If the gear can be engaged, contact the GENIE
Technical Assistance Service.
Proceed on one outrigger at a time.
•
With the outriggers up, light
A
on the load limiter
panel must be off; with the outriggers down to the
ground, the same light must be on. Should it not be
the case, contact the GENIE Technical Service.
DANGER
If a limit switch is faulty or a lever is deformed,
immediately replace the part.
■
Checking the machine start control
(at every use)
Attempt to start the engine with the forward or reverse
gear put.
The engine must not start. If the engine starts, contact
the GENIE Technical Service.
Repeat the operation putting first one gear, then the
other.
■
Checking the operation of the emergency pump
(weekly)
If the machine is equipped with an emergency pump,
check it is in efficient working order every week.
This pump is not used regularly and, as a result, it could
get damaged and be out of order in case of need.
To check that the pump is in efficient order, stop the
engine, press the on-off button for some seconds and
check that the pump works regularly.
A
17
Summary of Contents for Genie GTH-4013
Page 2: ......