5 Installation of generator
5.7 Installing and connecting the electrical box and rocker switch
340-1560-12.65-91
3
4
1
6
5
2
Parts required for electrical box
Have these parts ready:
1) Connecting
cable
2) Electrical box and support
3) Rocker
switch
4) Corrugated hose holder
5) Screws
6) Cover for corrugated hose holder
340-1560-12.65-76
2
1
3
Installing the rocker switch (view of cab)
Installing the rocker switch in the operator
panel
Remove the screen (2) on the operator
panel (1).
Remove the X67 connection cable and
connect to the rocker switch (3).
Insert the rocker switch (3).
340-1560-12.65-92
3
2
1
5
4
Electrical box and support
Attaching the electrical box
Remove the cover (4) from the MMI elec-
trical box (1).
Align the electrical box with the fastening
holes (3) on the support (5).
Tighten the electrical box from above with
the screws (2) on the support (5).
Fasten the cover (4) again.
12.65-SA10403-en-110808
Version 11.08.2008
29 (60)