5 Installation of generator
5.5 Installing the generator
340-1560-12.65-02
2
1
Fixing points for generator
Raising the generator
j
WARNING
Risk of crushing by falling
generator
• Only use lifting equipment that is
suitable for the weight (for
information on the lifting
equipment, refer to on page 9).
• Do not step under or put your
hands beneath the generator
when it is raised.
• Set the generator down without
delay.
In emergency: Provide first aid.
Consult a doctor immediately.
Position the lifting device (1) on the
eyebolt (2).
340-1560-12.65-03
1
2
4
3
Placing the generator on the generator plate
Placing the generator on the generator
plate
Set the generator plate on the industrial
truck so that the recess (1) is pointing to
the right and all elongated holes (4) are
accessible from below.
Move the generator with drive shaft (2)
forward onto the generator plate so that
the generator's front fastening holes (3)
line up with the front elongated holes (4).
340-1560-12.65-05
1
2
3
Generator fastenings
Fastening the generator loosely
Place the threaded links (1) on the fasten-
ing holes of the generator from above.
Screw in the hexagon bolts (3) with wash-
ers (2) loosely from below.
12.65-SA10403-en-110808
Version 11.08.2008
19 (60)