5 Installation of generator
340-1560-12.65-22
2
1
Setting the V-belt in place (view: fan side); shielding plate is
not shown for reasons of clarity.
Setting the V-belts in place
Set the V-belt in place on the V-belt pulleys of
the engine (1) and generator (2).
340-1560-12.65-12
1
2
3
Aligning the upper tensioning pulley (view: fan side; right)
Aligning the upper tensioning pulley and
tightening the bolts
Swivel the upper tensioning pulley in onto
the V-belts.
Align the tensioning pulley to the engine.
To do this, place the long ruler against the
tensioning pulley (2) and V-belt pulley on
the engine (1).
Tighten all fastening screws at the base of
the tensioning pulley support (3).
1
2
3
340-1560-12.65-11
Aligning the lower tensioning pulley (view: fan side; right)
Aligning the lower tensioning pulley and
tightening the bolts
Swivel the lower tensioning pulley in onto
the V-belts.
Align the tensioning pulley to the engine.
To do this, place the short ruler against the
tensioning pulley (2) and V-belt pulley on
the engine (1).
Tighten all fastening screws at the base of
the tensioning pulley support (3).
26 (60)
Version 11.08.2008
12.65-SA10403-en-110808