4 Preparations
4.3 Switching off and securing the machine
340-1560-12.65-52
1
Battery disconnect switch (view: service ladder)
n
DANGER
Electrical shock causing death
• Do not perform any assembly
work while the machine is run-
ning.
• Do not insert the magnet cable
into the generator until the cou-
pler socket is connected.
In emergency: Provide first aid.
Consult a doctor immediately.
Apply parking brake.
Switch off the machine.
Place a sign at the machine reading "Re-
pair work".
Turn the key (1) at the battery disconnect
switch by 90° to the left and pull off.
Keep the key at a safe place where it is
protected against unauthorized access,
but can easily be found.
4.4 Prior to beginning with the work
Allowing the machine to cool down
j
WARNING
• Le
Danger of burning by hot en-
gine parts.
t the machine cool down for a
sufficient time.
• Do not touch hot surfaces.
• Before loosening any connec-
tions, make sure that fuels, lu-
bricants, coolants and fuels con-
tained in these have cooled
down.
In emergency: Provide first aid.
Consult a doctor.
12.65-SA10403-en-110808
Version 11.08.2008
13 (60)