21. MANUAL PULS TIG SET
SELECT MANUAL PULSE TIG MODE:
With the first push button, select TIG PULSE.
SELECT ALL THE OTHER PARAMETERS:
PULS TIG is a different session and have its
own Torch switch cycle, and second level pa-
rameters, they will be recovered when Manual
PULS TIG is selected, adjust all off them, as in
Manual Tig.
SELECT THE FREQUENCY:
With the forth push button is possible also to
select the frequency of pulsation and adjust it
The adjustment is from 0,2 Hz up to 2 KHz.
SELECT PULSE TIG PARAMETERS:
For the expert welders is also possible to adjust
The parameters of pulsation as :
I LOW (background current during pulsation) and
Balance ( ratio between ON and OFF in the pulse).
The peak pulse is self calculate by the processor