ALARM
PROBLEM
SOLUTION
C22
Brush protection short circuit:
inhibits all functions.
Resettable only by pressing the OFF button of the
machine.
C14
Thermal overload cutout: trips
when the temperature rises
above 194 °F
Error condition resets automatically when the
temperature drops below 176 °F
FS0
Brushes worn
Replace brushes.
SP1
Brushes KO
Error resettable only by switching off the machine.
Trips if the brushes cut out (SHUTDOWN) three times
within the space of one minute.
cP
Communication Problem
Communication error between power and panel
boards, check the connection cable and power board.
Yellow Led alight
Battery reserve charge
Error condition that does not inhibit any function: the
condition is indicated by the yellow Led lighting up.
Red Led blinking
Reserve charge depleted
Error condition inhibiting all functions: resettable only
by pressing the OFF button of the machine.
E1.2 Display circuit board troubleshooting