TECHNICAL OFFICE
D1.6 Checking the connection between display circuit board and
power circuit board
Checks
1
Move the machine onto flat and dry flooring.
2
Make sure that there is enough room around the machine to perform the test safely.
3
Undo the fixing screws of the top cover, and remove the cover.
4
Disconnect the two battery connectors (red and black).
5
Expose the display circuit board as described in the previous heading.
6
Reconnect the two battery connectors (red and black).
7
Apply a jump across
PIN 1
and
PIN 6
of the display circuit board wiring connector.
7a
If the machine starts up, then the connection is good; if not, there is a problem with the display pcb.