![tennat NOBLES S6 Technical & Service Manual Download Page 46](http://html1.mh-extra.com/html/tennat/nobles-s6/nobles-s6_technical-and-service-manual_1087403046.webp)
November 30, 2020
46
of
58
PLDC04348
REVISION 00
November 09, 2020
TECHNICAL OFFICE
Technical Programming
Versions with 115 V
AC
/ 230 V
AC
Power Supply
B
C
D
E
A
PROCEDURE
1
Switch the machine on using the ON-OFF button
A
and then switch it off, holding the ON-OFF button
A
until the
first parameter is shown - U1.3.
2
To modify the parameter on the display, press the SUCTION button
C
to increase the value or press the FILTER
SHAKER button
D
to decrease the value.
3
To move to the next parameter, press the DISPLAY button
B
, the display will then show U2.4, UA.1, UB.0, Y0.3,
Y1.2, Y2.5, Y3.1 in a cycle back to U1.3.
4
To save the changes and exit, press the DISPLAY button
B
until the display switches off.
5
To exit without saving the changes, press the ON-OFF button
A
until the display switches off.
Parameter Indications and Available Values
U1.X
Actuator reaction time program 1 with value X from 0 to 9. It is not recommended to change the default
value.
U2.X
Actuator reaction time program 2 with value X from 0 to 9. It is not recommended to change the default
value.
UA.X
Type of battery installed: 0 = Acid / 1 = Sealed Acid - AGM / 2 = Gel. This is modified based on the battery
installed, if different from the one supplied with the machine.
UB.X
Enable display of technical parameters. 0 = Not enabled / 1 = Enabled
Y0.X
Brush adjustment tolerance with value X from 0 to 9. It is not recommended to change the default value.
Y1.X
(Jack lowering speed with value X from 0 to 9) Not used.
Y2.X
Jack rising speed with value X from 0 to 9. It is not recommended to change the default value.
Y3.X
Reset hour counter. Press for 10 seconds the BRUSH 1 button
E
to reset. If reset is successful, the buzzer
will sound continuously for 3 seconds.
DEFAULT VALUES
U1.3
U2.4
UA.1
UB.0
Y0.3
Y1.2
Y2.5
Y3.1
Summary of Contents for NOBLES S6
Page 2: ......
Page 4: ...PLDC04348 REVISION 00 November 09 2020 TECHNICAL OFFICE...