OPERATION
12
Tennant T3e (09--08)
IMPORTANT:
NEVER turn the FaST/ec--H2O system
switch on when conventional scrubbing. Conventional
cleaning detergents/restorers may cause failure to the
FaST/ec--H2O solution system. Drain, rinse and refill
solution tank with cool clean water before operating the
FaST/ec--H2O system.
FIG. 16
4. Lower the squeegee assembly to floor by lowering
the squeegee lift lever (Figure 17).
The vacuum
motor will automatically turn on.
FIG. 17
5. Lower the scrub head to the floor by stepping on
the scrub head lift pedal as shown (Figure 18).
FIG. 18
6. Pull the activation bail towards you to start
scrubbing (Figure 19). The drive model will
automatically propel forward. To reverse the drive
model, simply push the activation bail forward.
Drive Model--Reverse
FIG. 19
7. Drive Model: Adjust the speed control knob to a
desired scrubbing speed (Figure 20).
NOTE:
45--60 meters per minute is the recommended
scrubbing speed.
FIG. 20
8. For conventional scrubbing, turn the solution flow
control knob to a desired flow rate (Figure 21).
NOTE:
For the FaST and ec--H2O models, the solution
flow rate is fixed and requires no adjustment.
The ec--H2O module has optional flow rate settings. If
solution flow adjustments are required, contact an
Authorized Service Center.
FIG. 21