OPERATION
16
Tennant T3e (03--08)
BATTERY CHARGER SPECIFICATIONS:
S
CHARGER TYPE:
-- FOR SEALED (Gel) BATTERIES
-- FOR WET (Lead Acid) BATTERIES
S
OUTPUT VOLTAGE - 24 VOLTS
S
OUTPUT CURRENT - 11 AMPS
S
AUTOMATIC SHUTOFF CIRCUIT
S
FOR DEEP CYCLE BATTERY CHARGING
USING THE ON--BOARD BATTERY CHARGER
IMPORTANT: If your machine is equipped with the
on--board battery charger, make sure the charger
profile is properly set for your battery type before
charging. Failure to properly set will result in
battery damage.
To determine your battery type, see battery label.
Contact your battery supplier if not specified.
To verify the setting of the charger profile, connect the
charger cord into an electrical receptacle. If the LED
labeled “GEL” is on, the charger is set for Gel (sealed)
batteries. If the LED is off, the charger is set for
Wet/lead acid (flooded) batteries (Figure 33).
GEL LED
FIG. 33
To change the charger profile, unplug the charger,
remove the “Charger Profile Selection” panel and
position the switch towards the proper setting, “GEL” or
“Flooded” (Figure 34).
Charger Profile
Switch
FIG. 34
1. Transport the machine to a well--ventilated area for
charging.
2. Park the machine on a flat, dry surface. Turn the
key off and set the parking brake, if equipped.
3. If charging wet (lead acid) batteries check the fluid
level before charging (See BATTERY
MAINTENANCE on page 24).
4. Connect the charger cord into a properly grounded
electrical receptacle (Figure 35). The charger will
start automatically within a few seconds. The LED’s
will display the charging state as described in the
following table.
NOTE:
The machine will not operate once the battery
charger is connected.
Charging State
LED Display
FIG. 35
CHARGING STATE LED DISPLAY
Charging State
50% LED
75% LED
100% LED
0--50% charged
Blinking
Off
Off
50--75% charged
On
Blinking
Off
75--100% charged
On
On
Blinking
100% charged
On
On
On
Abnormal Cycle*
Off
Off
Blinking
Fault detected *
Blinking
Blinking
Blinking
* See the On--board Battery Charger Fault Codes table. When
a fault occurs, the charger will also sound an alarm.