MAINTENANCE
3-10
275 SERIES II MM190 (12---89)
Check the hydraulic fluid level after every
100 hours of operation. It should be above the “add”
marks on the dipstick, but not above the “full” mark
when the hydraulic fluid is warm.
Do not overfill the hydraulic fluid reservoir. Hydraulic
fluid expands as it heats to its normal operating
temperature. Always allow for expansion when filling
the reservoir.
ATTENTION! Do not overfill the hydraulic fluid
reservoir or operate the machine with a low level
of hydraulic fluid in the reservoir. Damage to the
machine hydraulic system may result.
Drain and refill the hydraulic fluid reservoir with
hydraulic fluid after every 400 hours of operation.
The hydraulic system is kept clean to a level of
10 microns by a hydraulic fluid filter. The hydraulic
fluid filter is located under the radiator. Replace the
filter element after every 400 hours of operation.
A reservoir outlet strainer is built into the reservoir to
filter hydraulic fluid before it enters the system.
Replace the strainer after every 800 hours of
operation.
TO DRAIN HYDRAULIC FLUID RESERVOIR AND
REPLACE FILTER ELEMENT
1. Stop the engine and set the machine parking
brake.
FOR SAFETY: Before leaving or servicing
machine; stop on level surface, set parking brake,
and turn off machine.
2. Allow the hydraulic fluid to cool.
3. Unthread and discard the hydraulic fluid filter
element. Hydraulic fluid will drain through the
filter head. Discard the used hydraulic fluid.
A
B
04623
HYDRAULIC FLUID FILTER
A. Filter Element
B. Machine Frame
NOTE: Be aware the hydraulic filter is lower than the
reservoir. All fluid will drain from the reservoir.
Discard all hydraulic fluid drained from the system. It
may contain foreign material harmful to the hydraulic
system.
4. Apply a thin coat of hydraulic fluid to the seal of
the new hydraulic fluid filter element.
5. Thread and hand tighten the new hydraulic
fluid filter element on the filter head.
6. Operate the machine and check for leaks.
Correct any leaks found.
7. Check the hydraulic fluid reservoir level and fill
as required.
Summary of Contents for 275 Series II
Page 1: ...r 275 Series II Sweeper Scrubber ...
Page 6: ...ABOUT THIS MANUAL 275 SERIES II MM190 12 89 d ...
Page 18: ...SPECIFICATIONS 1 2 275 SERIES II MM190 12 89 ...
Page 22: ...SPECIFICATIONS 1 6 275 SERIES II MM190 12 89 ...
Page 24: ...OPERATION 275 SERIES II MM190 12 89 2 2 ...
Page 74: ...MAINTENANCE 3 14 275 SERIES II MM190 12 89 04644 HYDRAULIC SCHEMATIC LOW DUMP MODEL ...
Page 75: ...MAINTENANCE 3 15 275 SERIES II MM190 12 89 04645 HYDRAULIC SCHEMATIC MULTI LEVEL DUMP MODEL ...
Page 97: ...MAINTENANCE 3 37 275 SERIES II MM190 12 89 04643 ELECTRICAL SCHEMATIC DIESEL ...
Page 98: ...MAINTENANCE 3 38 275 SERIES II MM190 12 89 04642 ELECTRICAL SCHEMATIC ACCESSORIES ...
Page 99: ...MAINTENANCE 3 39 275 SERIES II MM190 6 90 06187 ELECTRICAL SCHEMATIC AUTO SHAKER RFS ...
Page 100: ...MAINTENANCE 3 40 275 SERIES II MM190 6 90 06187 ELECTRICAL SCHEMATIC AUTO SHAKER RFS ...