background image

www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk

TM

TM

Page <24>

V1.0

26/04/18

The temperature measurement ranges have ″-20°C to 150°C″ and ″0°C to 400°C″ to choose. The overlap temperature of the 

two ranges Is more accurate to choose ″-20°C to 150°C″.
The  ambient  temperature,  humidity  and  reflection  temperature  are  Important  for  radiometric  temperature  measurement. 

Thermal Imager has temperature compensation for these values. To get more accurate temperature measurement, accurately 

set the ambient temperature, humidity and reflection temperature. In most cases, the reflected temperature is identical to 

the ambient temperature. Only when objects with strong emissions with much higher temperature are in the proximity of the 

object being measured, the reflected temperature is different of the ambient temperature and must set the temperature of 

environment.

Press ″Measure setting″ to popup the submenu of Measure Setting. ″Lens″ display current optical infrared lens; ″Range″ sets the 

range of temperature measurement; ″Env″ sets ambient temperature; ″Humid″ sets humidity; ″Ref″ sets reflected temperature.

Alarm

Thermal Image has alarm function to beep. There are 3 kinds of alarm mode: ″Above″, ″Below″ and ″Equal″. The ″Above″ mode 

will start to alarm when temperature Is above to setting temperature; The ″Below″ mode will start to alarm when temperature is 

below to setting temperature; The ″Equal″ mode will start to alarm when temperature is equal to setting temperature.

Alarm open and close

Press  “Alarm”  to  open  temperature  alarm,  The  Icon  ″ 

  ″ 

means to open, The Icon ″   ″ means to close.

Alarm Settings

Press the icon ″   ″ to popup submenu of Alarm Settings.

Target

:  

Sets the target of temperature alarm, there are 

3 kinds of choices; Spot 1, Spot 2, Spot 3;

Mode

:

 Sets the alarm mode, ″Above″, ″Below″, ″Equal″.

Temp

:

 Sets alarm temperature value.

7.4 - 

Camera Menu

Thermal Imager has photo and video functions. In photo 

function, the Imager can save thousands of images. Every 

image resolution is 640*480, format is .jpg and stores infrared 

data and visible data in an image. In video function, the Imager 

has .mp4 video capture for hours, and save infrared data in 

.mp4 format.

Note:

Images and video flies are stored In SD Memory Card. Images 

can easily be read and second analyzed within Thermal 

Imager PC software.

In main menu, press camera icon ″   ″ ,popup Camera Menu 

which contains Snapshot Menu and Video Menu. Slide the 

rectangle in the icon ″ 

 ″ from left to right to switch form 

Summary of Contents for 72-13455

Page 1: ...www element14 com www farnell com www newark com www cpc co uk TM TM Page 1 V1 0 26 04 18 Thermal Imager User Manual Part Number ST 9875 ...

Page 2: ...ing 8 5 4 Interface 9 6 Before You Start 9 6 1 How to Charge the Battery 9 6 1 1 Battery Charger Base 9 6 1 2 AC Power Socket 9 6 2 Power On and Off 10 6 3 Main Interface 10 6 4 Optical Lens 10 6 5 Focus 11 6 6 Shutter 12 6 7 Temperature Measurement 12 6 8 Emissivity Adjustment 12 6 9 Reflected Temperature 12 6 10 Thermal Imager Reporter Software 13 7 Menus 13 7 1 Main Menu 13 7 2 Image Menu 14 7 ...

Page 3: ...ment 21 7 3 4 Measurement Settings 22 7 4 Camera Menu 24 7 4 1 Snapshot Menu 25 7 5 Video Menu 26 7 6 Photos Browser 26 7 6 1 Multi Photos Browser 26 7 6 2 Single Photos Browser 27 7 7 Player Menu 27 7 8 Settings Menu 28 7 8 1 General Page 28 7 8 2 Control Page 29 7 8 3 Photos Page 31 7 8 4 Date Time Page 31 7 8 5 Info Page 32 7 9 Factory Settings 32 8 Fault diagnosis and exclusion 33 ...

Page 4: ...le or do a modification to the battery The battery contains safety and protection devices which if they become damaged can cause the battery to become hot or cause an explosion or an ignition If there is a leak from the battery and the fluid gets into your eyes do not rub your eyes Flush well with water and immediately get medical care Do not make holes in the battery with objects Do not hit the b...

Page 5: ...ager 1 Lens 1 Field of view 29 8 22 6 f 7 5mm Lens Cover 1 Led Hood 1 Tripod Base 1 Lithium polymer battery 1 7 4V 2600mAH Adaptor 1 Input AC Volts 100V to 240V 50 60Hz MAX 0 8A Output DC Volts 12V 3000mA Charger 1 Micro SD 1 4GByte USB cable 1 RCA cable 1 Earphone 1 User manual 1 Warranty Card 1 PC software Installation CD 1 Gift box Carrying case 1 Imaging And Optical Data Field of view FOV Mini...

Page 6: ...ot cold detection Auto hot or cold markers Isotherm Detect high low temperature interval Emissivity correction Variable from 0 01 to 1 0 Measurement corrections Emissivity ambient temperature distance relative humidity offset temperature Storage of Videos Storage media 4GBytes Micro SD card Video storage format Standard MPEG 4 640 480 30fps on memory card 60 minutes Video storage mode IR visual im...

Page 7: ...d NTSC Power System Battery Lithium Polymer Battery 4 5 hours operating time Input voltage DC 9V to 12V Charging system In Camera AC Adapter Power management Automatic shutdown and sleep mode User Selectable Environmental Data Operating temperature range 20 C to 50 C 4 F to 122 F Storage temperature range 40 C to 70 C 40 F to 158 F Humidity operating and storage 10 to 90 Encapsulation IP65 Drop te...

Page 8: ...co uk TM TM Page 8 V1 0 26 04 18 5 2 Front View 6 LED Light 7 Visual Camera 8 Laser Pointer 9 Infrared Camera Lens Lock 10 Infrared Camera Lens 5 3 Assembly drawing 11 Liquid Crystal Display Hood 12 Thermal Imager 13 Tripod Base 14 Lens Cap for Infrared Lens ...

Page 9: ...and connect the DC output to the Thermal Imager s AC power socket The battery indicator becomes in the upper right comer of the display while the battery charges with the AC power adapter 2 Charge until the charge indicator on the display becomes 3 Disconnect AC power adapter when the battery is full charged Note Make sure that the Thermal Imager is near room temperature before you connect it to t...

Page 10: ...sufficient warm up time for the most accurate temperature measurements and best Image quality This time can often vary by environmental conditions It is best to wait a minimum of 10 minutes if the most accurate temperature measurement is very important to your application 6 3 Main Interface The Main Interface Is as follow 6 4 Optical Lens The Thermal Imager has 4 kinds of Optical Lens To change le...

Page 11: ...asure Typically D S measure is 2 to 3 times smaller than D S theoretical which means the temperature measurement area of the target need to be 2 to 3 times larger than that determined by the calculated theoretical D S Note IFOV theoretical represents the smallest objects that the Thermal Imager can detect or see IFOV measure represents the smallest object form which an accurate temperature can be ...

Page 12: ... usually allow the Thermal Imager to calculate a more accurate estimate of the actual temperature More information please see Emissivity Adjustment to get the most accurate temperature measurements 6 8 Emissivity Adjustment The correct emissivity value is important to make the most accurate temperature measurement Emissivity of a surface can have a large effect on the apparent temperatures that th...

Page 13: ...he Thermal Imager This Software is intended for Thermal Imager and contains feature to analyze images organize data and information and make professional reports Thermal Imager Reporter software allows audio annotations and commentary to be reviewed on a PC 7 Menus The menus together with buttons are access for image measurement camera photo play and settings 7 1 Main Menu Main Menu Is the main In...

Page 14: ... VIS_Mix_IR IR Displays only infrared image Visible Displays only visible image IR_PIPE_VIS and VIS_PIPE_IR Display infrared and visible image at the same time IR_Mix_VIS and VIS_Mix_IR Display fusion image of infrared and visible images In Image Menu press the Icon shows the page of Image Mode Press left arrow or right arrow to change image mode In IR_PIPE_VIS and VIS_PIPE_IR mode There are four ...

Page 15: ...ow user to customize personal palettes In Image Menu press the icon shows the page of Image Palette There are two groups of palette Standard Palette and Custom Palette The icon represents the current image palette In the corresponding group Standard Palette Press Standard bar Popup the standard palette submenu It shows eight kinds of palettes they are IRON Rainbow Grey Grey Inverted Sepia Blue_Red...

Page 16: ...y current palette The every colour value is based on liner gradient 0 0 item displays the minimum value 50 0 displays the maximum value There are 3 scales which the value is based on position the minimum value and maximum value Press and move every scale can change the position Press 0 0 or 50 0 to show menu for minimum or maximum parameter settings Min Value shows the minimum value Max Value show...

Page 17: ...switched off unchecked it means to disable linear gradient in this scale the icon will hide 7 2 3 Image Adjustment There are 3 kinds of modes for thermal image adjustment they are All Auto Histogram Manual Press left arrow or right arrow to change image adjustment All Auto level and span are decided by the thermal image of minimum temperature and maximum temperature Histogram level and span are de...

Page 18: ...s the icon popup the submenu of ISO settings This submenu contains settings for Isothermal mode Isothermal temperature Isothermal range and Isothermal colour Isothermal mode has Inter Above Below The Inter mode means infrared image which the temperature in the range of Level Width 2 Level Width 2 is set to Colour The Above mode means the infrared image which the temperature is greater than Level W...

Page 19: ...d of rotation When rotated an angle the angle of rotation displays in the upper right corner of the display 7 3 Measurement Menu In main menu press measurement icon popup Measurement Menu which contains Point Measurement Line Measurement Area Measurement and Measurement Settings Point Measurement Measure the selected points each point can move capture maximum temperature and minimum temperature Li...

Page 20: ...uring The Icon means to select The Icon means to not select When the point selects to use global parameters for measuring Emiss Distan Offset becomes disabled When the point selects to use private parameters for measuring Emiss Distan Offset becomes enabled Emiss sets object emissivity the value range is 0 01 to 1 00 Distan sets object distance the value range is 0 to 5000 Offset sets object offse...

Page 21: ...ne selects to use private parameters for measuring Emiss Distan Offset becomes enabled Emiss sets object emissivity the value range is 0 01 to 1 00 Distan sets object distance the value range is 0 to 5000 Offset sets object offset the value range is 100 C to 100 C 7 3 3 Area measurement In measure menu press the icon show the page of Area Measurement There are 3 areas to measure Each area has the ...

Page 22: ...up the submenu of the area parameters Press use global para to use global parameters for measuring The Icon means to select The Icon means to not select When the area selects to use global parameters for measuring Emiss Distan Offset becomes disabled When the point selects to use private parameters for measuring Emiss Distan Offset becomes enabled Emiss sets object emissivity the value range is 0 ...

Page 23: ...press No to cancel Factory parameters Measurement Setting The menu of Measurement Settings displays current infrared optical lens and also has adjustments for temperature measurement range ambient temperature humidity and reflection temperature Thermal Imager has 4 kinds of lens 7 5mm 11mm 22mm and 33mm 7 5mm is the standard accessory others are optional for user Global Measure Parameters Emissivi...

Page 24: ...ermal Image has alarm function to beep There are 3 kinds of alarm mode Above Below and Equal The Above mode will start to alarm when temperature Is above to setting temperature The Below mode will start to alarm when temperature is below to setting temperature The Equal mode will start to alarm when temperature is equal to setting temperature Alarm open and close Press Alarm to open temperature al...

Page 25: ...pper right comer of the screen will show the icon Save Image When the image is frozen Press the icon Thermal Imager will save an image if Thermal Imager have inserted SD Memory Card After saving image the icon becomes back to the icon Note There is a quick way to save the image Press key Button to save an image Sound Recording 1 In snapshot menu after saved an image the icon becomes enabled and th...

Page 26: ...e icon popup Photos Browser Which displays images that save in SD Memory Card 7 6 1 Multi Photos Browser Slide touch screen from right to left displays previous page Slide touch screen from left to right displays next page Press the HOME button to exit Photos Browser Press delete to show delete menu Press an image to select the image shows the icon then press delete to delete selected image Press ...

Page 27: ...om in 3 Slide the touch screen to move the image 4 Press the icon to rotate the image press but not release the image will continue to rotate 5 Press the icon to zoom out the image press but not release the image will continue to zoom out 6 Press the icon to delete the image 7 Press the icon to exit photos Browser 7 7 Player Menu The Player Menu previews deletes and plays video files In Main Menu ...

Page 28: ...Player Menu Press the video file to play the menu shows as 1 The icon is used to stop playing 2 The icon is used to play 3 The icon is used to popup Player Menu for previewing video files 4 The icon is used to adjust volume slide up the slider to increase volume slide down the slider to decrease volume 5 The icon is used to exit the Player Menu 7 8 Settings Menu In main menu press the Icon popup t...

Page 29: ...mperature precision has Single Double to select When selecting Single the temperatures of display will have 1 decimal When selecting Double the temperatures of display will have 2 decimal Temperature Unit Set temperature unit has C F K to select Conversion relationship F 1 8 C 32 K 273 15 C Distance Unit Set distance unit has M FT to select Conversion relationship FT 0 3048 M 7 8 2 Control Page Th...

Page 30: ...popup submenu of setting LCD brightness Auto Shutter Set the time period of auto shutter has 30 seconds 1 minutes 2 minutes to select OFF means to close auto shutter Screen Off The Thermal Imager will close LCD power after LCD screen time of inactivity There are 1 minutes 2 minutes 5 minutes to select for setting the lime for power of LCD OFF means to never close LCD power Note When LCD power is p...

Page 31: ...f inactivity There are 5 minutes 10 minutes 30 minutes to select for setting shut down time OFF means to never shut down 7 8 3 Photos Page The Thermal Imager can auto save photos When the period is set a value the Thermal Imager will auto save photos in interval given value 7 8 4 Date Time Page Data Time Page has adjustments for Date Time AM PM Date Format ...

Page 32: ...ctory Settings Factory Settings of the Thermal Imager is as follow Item Parameter Value Measurement Spot Measurement Off Line Measurement Off Area Measurement Off Isothermal Analysis Off Measurement Parameters Emissivity 0 95 Distance 5m Ambient Temperature 250C Reflected Temperature 250C Humidity 60 Offset 0 0 C Image Mode Infrared Palette Iron Adjustment Auto System Setting Language English Anal...

Page 33: ...ormation purposes in connection with the products to which it relates No licence of any intellectual property rights is granted The Information is subject to change without notice and replaces all data sheets previously supplied The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness any error in or omission from it or for any us...