Set Point Mode
Press the icon ″ ″ popup the submenu of the point mode.
Press ″Manual″ to select manual mode, current points
icon ″ ″ becomes ″ ″ Press ″Max″ to select maximum
temperature capture mode, current point’s icon becomes
red icon ″
″; Press ″Min″ to select maximum temperature
capture mode, current point’s icon ″
″ become green icon;
The Icon ″ ″ means to select, The Icon means to not select.
Set Point Parameters
Press the icon ″
″, popup the submenu of the point
parameters. Press ″use global para″ to use global
parameters for measuring. The Icon ″
″ means to select
The Icon ″ ″ means to not select.
When the point selects to use global parameters for measuring,
″Emiss″, ″Distan″, ″Offset″ becomes disabled. When the point
selects to use private parameters for measuring, ″Emiss″,
″Distan″, ″Offset″ becomes enabled. ″Emiss″ sets object
emissivity, the value range is 0.01 to 1.00; ″Distan″ sets object
distance, the value range is 0 to 5000; ″Offset″ sets object
offset, the value range is -100°C to 100°C;
7.3.2 -
Line Measurement
In measure menu, press the icon ″ ″,show the page of Line
Measurement. There are 2 lines to measure. Each line can
use global parameter settings or private parameters to set the
measuring parameters.
Open and Close
Press ″Hor Line″ to open horizontal line and press ″Ver Line″
to open vertical line. The Icon ″
″ means to open, The Icon
″ ″ means to close.