www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
TM
TM
Page <14>
V1.0
26/04/18
Settings:
Set for the user preferences such as language, unit of temperature measurement, unit of distance, date, time and
some other settings.
Push HOME ″ ″ button or press blanks of the main interface, popup the Main Menu. When main menu has displayed, Push
HOME ″ ″ button or press blanks of the Main Menu, hide the Main Menu.
7.2 -
Image Menu
In main menu, press image icon ″ ″, popup Image Menu which contains Image Mode, Image Palette, Image Adjust and Image
Setting.
7.2.1 -
Image Mode
Thermal Imager has 6 kinds of image modes for display. IR/Visible/IR_PIPE_VIS/
VIS_PIPE_IR/IR_Mix_VIS/VIS_Mix_IR.
IR:
Displays only infrared image;
Visible:
Displays only visible image;
IR_PIPE_VIS and VIS_PIPE_IR:
Display infrared and visible image at the same
time;
IR_Mix_VIS and VIS_Mix_IR:
Display fusion image of infrared and visible images.
In Image Menu, press the Icon ″ ″, shows the page of Image Mode. Press left
arrow or right arrow to change image mode.
In IR_PIPE_VIS and VIS_PIPE_IR mode, There are four options for image pipe
position: Topleft, Bottomleft, BottomRight, TopRight. ln ″Position:XX″ item, Press left
arrow or right arrow to change image pipe position.
Note:
TL:
Topleft; BL:Bottomlef; BR:BottomRight; TR:TopRight.
In IR_Mix_VIS and VIS_Mix_IR mode, In ″Size: XX″ item, press left arrow or right
arrow to change image mix size. There are two options: Half or Full. In ″Blend:XX%″
item, press left arrow or right arrow to change image mix percentage. The range is
0% to 100%.