Set Manual AGC Attenuation
BFO (C2)
Format:
(Set command)
*
C2nnnn<cr>
(Get command)
?C2nnnn<cr>
Definitions:
For CW detection mode operations, The Beat Frequency Oscillator (BFO) capability is available. The
BFO is adjustable over a +/- 8192 Hz range in 1Hz steps. The BFO frequency can be applied to the
received CW signal to alter its audio pitch as a detection aid. The BFO frequencies are selected by the
BFO commands.
Sets the amount of AGC attenuation to apply. Adjusts from 000-120 dB range with 0.10 dB
resolution. Can be set in any mode. Receiver gain is reduced and AGC threshold is increased
by the number of dB indicated.
Format
:
(Set command)
*
C1AAAD<cr>
(Get command)
?C1<cr>
Response: C1AAAD<cr>
1)
Definitions:
AAA= 000-120 represents the amount of attenuation in db. Range 000-120
D=represents .10 resolution for the attenuation. Example: 107.8 dB attenuation will
be entered as 1078. Decimal point is not allowed.
7-6