Store Current Parameters in Memory Channel (P1)
Format:
(Set command)
*P2SSSEE<cr>
1)
(Get command)
?P2<cr>
Response:
P2SSSEE<cr>
Definitions:
SS= Specifies the starting channel for the memory scan via two ASCII digits. Range 0-999.
EE= Specifies the ending channel for the memory scan via two ASCII digits. Range 0-999.
Format:
(Set command)
*P3CCCX<cr>
1)
(Get command)
?P3CCC<cr>
Response:
P3CCCX<cr>
Definitions:
CC=specifies the channel to be added or deleted to the memory list when scanning. Range 0-
999
X= <A> adds the specified channel to the memory list when scanning.
= <S> removes the specified channel from the memory list when scanning.
Format:
(Set command)
*P1CCCBBMSSRFFFFFFFFFF<cr>
1)
(Get command)
?P1CCC<cr>
Response:
P1CCCBBMSSRFFFFFFFFFF<cr>
Definitions:
CC
=Channel Number to assign parameters. Range 00-999 in ASCII/decimal format
BB
=Selected IF Bandwidth filter number assigned to the specified channel number. Range: (See Table 5)
M
=Selected detection mode assigned to the specified channel <A>=AM, <F>=FM, <U>=USB,
<L>=LSB,
<C>=CWU, <W>=CWL, <K>=FSK
SS
=Selects the desired squelch mode settings. Multiple squelch modes can be selected.
R
=<A>=channel specified in command is added to the channel ring.
=<D>=channel specified in command is deleted from the channel ring.
FFFFFFFFFF
=Frequency to tune assigned to specified channel number. Range 100kHz-3
GHz Leading zero’s can be omitted.
Memory-Scan Channel Start-Stop Range (P2)
Memory Channel Skip/Add (P3)
7-18