Dead Time (T2)
S-Meter Hold Off Time (T4)
7-21
Format:
(Set command)
*T2TTTTTTTT<cr>
(Get command)
?T2<cr>
Response:
T2TTTTTTTT<cr>
TTTTTTTT= represents the time in ASCII/decimal format. Value = number of milliseconds.
Valid ranges are 0-99999999.
Dead time refers to the time the radio will remain on a channel after activity has ended. The
factory default is 8 seconds. If the DWELL TIME setting is less than the DEAD TIME setting
the radio will resume scanning when the DWELL TIME timer runs out. If the DWELL TIME
setting exceeds the DEAD TIME setting, scanning will resume when the DEAD TIME timer
runs out.
Format:
(Set command)
*T3TTTTTTTT<cr>
(Get command)
?T3<cr>
Response: T3TTTTTTTT<cr>
TTTTTTTT= represents the time in ASCII/decimal format. Value = number of milliseconds.
Valid ranges are 0-99999999.
Gaze time is the time the radio will spend waiting for activity on each new channel or
frequency. The factory setting is 50Ms. This time can be adjusted to control the rate of scan.
Format:
(Set command)
*T4TTTTTTTT<cr>
(Get command)
?T4<cr>
Response:
T4TTTTTTTT<cr>
TTTTTTTT= represents the time in ASCII/decimal format. Value = number of milliseconds.
Valid ranges are 0-99999999.
This feature determines how long the radio will wait before checking channel activity after moving to
a new frequency or channel. This time is necessary to allow the AGC system to settle down so an
accurate measure of channel activity can be made. Factory defaults to 50ms.
Gaze Time (T3)