Temperature Control Unit : VTO Series with G500 Series Instrument
Page: 18
TEMPTEK, INC.
525 East Stop 18 Road Greenwood, Indiana 46142
317-887-6352 Fax: 317-881-1277
Email: [email protected]
WARNING: Check that all electrical connections are tight before starting.
Disconnect power before servicing. Follow all facility lock-out tag-out procedures.
Typical Electrical Panel shown as reference of a RK-1230H model. Refer to the electrical drawing available for specific model.
A
B
C
D
E
F
G
H
I
A
High temperature limit. Factory set to 515°F.
B
High temperature limit instrument relay.
C
Power entry terminal block.
D
Motor starter and overload block.
E
Transformer fuses.
F
Control transformer
G
Heater contactors
H
Water supply pressure switch
I
Power Cord.
Note : typically included on most 12 kW models with up to 3 HP pumps. Units with 16 kW to 48 kW
heaters and pumps do not include a power cord.