Sidekick
®
Plus Test Set
Synchronizing
Note: If Upper Layer tests will be performed, be sure the
WAN Setup is correct before modem synchronization.
Press the
F2 Connect
key to turn on power to the
modem and begin the synchronizing process.
The first page of results is the “Status” page. This
page is used to indicate the status of the physical layer
synchronization (SYNC) and the upper layer authentica-
tion (DATA). If the WAN section of the setup contains
the correct authentication information, the modem will
authenticate on the line after synchronization occurs.
In the header, you will notice icons “A” (ADSL), “V”
(VDSL), or “X” (Auto mode). If the modem is configured
for Auto mode, the icon will have an “X” in it until the
modem figures out what service is on the line; then it
will change to either “A” or “V.” The icon “D” indicates
DATA.
The status of the synchronization and authentication
are also shown in the two icons in the header at the top
of the screen. The letter in the SYNC icon will change
from “A” to “V” to indicate if the modem is connected
to a ADSL or VDSL circuit.
Two large SYNC boxes and two smaller icons are
displayed in bonded mode to show the status of each
bonded channel.
After the modem connection is established, the
F2
Disconnect
key will disconnect the modem.