![Tempo Communications 1155-5003 Instruction Manual Download Page 37](http://html1.mh-extra.com/html/tempo-communications/1155-5003/1155-5003_instruction-manual_1085712037.webp)
37
Sidekick
®
Plus Test Set
6. Press the right (
6
) key until the desired type is high-
lighted, or the keypad number key of the desired
type:
• Test Pair: Red and black leads.
• Test Pair/Reference Pair: Both test
(red/black) and reference (yellow/blue)
test leads are displayed.
• Test Pair/Difference/Reference Pair: The test,
reference, and difference (test-reference) pairs
are displayed simultaneously.
• Test Pair–Reference Pair: The difference of the
test and reference pairs is displayed.
• Test Pair (Intermittent): Continuously displays all
TDR traces to capture intermittent faults.
• Reference Pair: Yellow and blue leads.
7. Press the
O
(
Back)
key to select the type of test
and exit.
Changing the gain or cable length will affect all test
waveforms.
The illustration below shows both test and reference
waveforms.
Step TDR Functionality (optional)
On units that contain the Step TDR feature, the “Unit”
option in the TDR Config menu shows “Step TDR” as
option 2. This will switch the unit from displaying pulse
TDR information to step TDR information. The step TDR
feature is useful in discovering bridge taps and other
faults that are more difficult to see with a pulse TDR.