![Tempo Communications 1155-5003 Instruction Manual Download Page 58](http://html1.mh-extra.com/html/tempo-communications/1155-5003/1155-5003_instruction-manual_1085712058.webp)
58
Sidekick
®
Plus Test Set
4 Impulse Noise (optional)
Refer to “Appendix B”.
5 R/D Calculation
Pressing the
5
key provides the technician with a
resistance vs. distance calculator.
1. The up (
2
) and down (
8
) arrow keys highlight the
various possibilities. Enter correct pair type, wire
gauge and wire temperature with the left (
4
) and
right (
6
) arrow keys.
2. Enter the known resistance or distance by scrolling
down until the correct field is highlighted.
3. Press
F1 Edit
and enter the value desired.
4. When finished, press
F4 Done
.
•
F2 Calc R
calculates resistance.
•
F3 Calc D
calculates distance.
6 Tones
Pressing
6
while on the TOOLS MENU screen accesses
the Tones screen.