![Tempo Communications 1155-5003 Instruction Manual Download Page 42](http://html1.mh-extra.com/html/tempo-communications/1155-5003/1155-5003_instruction-manual_1085712042.webp)
42
Sidekick
®
Plus Test Set
Changing Gauge and Temperature
Press
F2 Setup
.
1. Use the up (
2
) and down (
8
) arrow keys to adjust
temperature displayed at the top in the center.
2. Once the correct temperature is displayed, press
F2 Setup
again.
3. Use the arrow keys to modify the wire gauge
displayed at the top right.
4. Press
F2 Setup
to exit.
Press
F1 Next
.
The display now shows the resistance to the conductor
connected to the yellow lead.
The gauge and temperature must also be set for the
yellow lead for distance measurement. Press
F2 Setup
to change gauge and temperature.
Press
F1 Next
.
The display now includes distance or resistance from
the test set to the fault.
Press
F1 Next
.
The display now includes distance or resistance from
the strap to the fault.
Verification
The Sidekick
®
Plus test set automatically verifies that
the previous measurements agree with each other. It
posts the result in the upper right corner.
• Verify Good: Distance-to-fault plus the fault-to-strap
equals the distance to strap.
• Verify Bad: Calculation was more than ±0.7% off.
• Verify Invalid: Verification is not possible in 3-wire
mode.
Summary of Contents for 1155-5003
Page 2: ......