![Tempo Communications 1155-5003 Instruction Manual Download Page 31](http://html1.mh-extra.com/html/tempo-communications/1155-5003/1155-5003_instruction-manual_1085712031.webp)
31
Sidekick
®
Plus Test Set
3-Lead
To obtain a 3-lead measurement, press
F3 3-Lead
while on the Length menu. The length or capacitance
measurement is displayed from the ring-to-tip, tip-to-
ground, and ring-to-ground in sequence, with the active
measurement in bold.
Return to the Single Pair screen by pressing the
F3 3-Lead
key.
Specifications for this measurement are the following:
Range: 0 to 30 km (0 to 100,000 ft)
0 to 30 m (0 to 99 ft)
• Resolution: 0.3 m (1 foot)
• Accuracy: 5%/0.6 m (5%/2 ft)
30 to 6095 m (100 to 19,999 ft)
• Resolution: 4 digits
• Accuracy: 4%
6096+ m (20,000+ ft)
• Resolution: 4 digits
• Accuracy: 10%
Changing Distance Units
The distance measurement may be toggled between
feet and meters through the F4 Setup screen.
1. Press
F4 Setup
.
2. If necessary, use the up (
2
) or down (
8
) arrow keys
on the keypad to highlight “Unit.”
3. Use the right (
6
) arrow key to toggle between
“Feet”, “Metres”, and “Capacitance”.
To exit back to the LENGTH function, press the
O
(
Back)
key.