6.4 Choice of installation place
•
Observe all the rules in force.
•
Install the product outside the building.
•
Don’t install the product:
- near a heat source,
- near flammable substances,
- near ventilation opening of contiguous buildings,
- Below deciduous trees.
•
For the installation of the product observe:
- prevailing winds,
- noise of the fan and the compressor,
- optical impression on the environment
•
Avoid place where on the air outlet of the product there is
the effect of strong winds.
•
Don’t orient the fan towards the near windows.
•
If necessary, install noise-protection system.
•
Install the product on one of the following supports:
- Concrete pavement,
- T steal beem
- Concrete block.
•
Don’t expose the product to dusty and corrosive air (e.g.
near rough roads).
•
Don’t install the product near wells of air discharge.
•
Prepare the laying of electrical cables.
•
In places where there are snowfalls, install the heat pump
at least 25 cm from the ground to avoid clogging at the
inlet and drain zone.
6.5 External unit mounting
1. Before installing the device, please see the safety warnings
in this manual.
2. Install the product on T beam steel, Concrete Block or with
a wall support.
3. Make sure that water doesn’t accumulate under the
device.
4. To avoid ice formation, make sure that the ground in front
of the device can absorb condensed water.
6.6 Condensate discharge preparation
The condensate is discharged behind the heat pump by a unique
way. Prepare the condensate discharge with a discharge pipe
or with a gravel bed.
WARNINGS!
Frozen condensate on the path can cause falls. Make sure that
the condensate doesn’t flow on the path and that it doesn’t
freeze.
•
Preparation of the base for condensate drain
•
Example 3 condensate drain (it is recommended to bury the
drain pipe to prevent the formation of ice in the event that
you do not
purchases optionally the heating resistor for
discharge condensate)
Frost proof
depth
min 200mm
Frost
proof
depth
Frost proof
depth
min 200mm
Frost
proof
depth
Frost proof
depth
min 200mm
Frost
proof
depth
Frost proof
depth
min 200mm
Frost
proof
depth