Templari KITA AIR Installation Instruction Download Page 26

26

www.templari.com

defrost made by the machine during the operation in heat 

pump.

E . CONFIGURATION BMS

This menu allows to set the communication protocol of the port 

“BMS“  of  the  electronic  control.  This  menu  is  protected  by  a 

password. Only the authorized staff can enter it.

F . ASSISTANCE PARAMETER

This menu is protected by a password. Only the athorized staff 

can enter it.

a. Counter settings

b. Sensors calibration

c. Thermoregulation

d. default user / change password

 

a. COUNTER SETTINGS

 

Reserved to the authorized staff

 

b. SENSORS CALIBRATION

Gfb01:  sensor calibration B1 and B2

Gfb02:  sensor calibration B3 and B4

Gfb03:  sensor calibration B5 and B6

Gfb04:  sensor calibration B7 and B8

For the sensor B8 it is also possible to choose:

• 

on board: the sensor on board is set

• 

remote: remote sensor is set

Gfb05:  sensor calibration B9 and B10

Gfb06:  sensor calibration B11 and B12

Gfb07:  offset S1, S2

Gfb08:  offset S3, S4

Gfb09:  enable and set sensor calibration B2 and B3

 

c. THERMOREGULATION

Mask Gfc02: 

Configuration  request  integration 

parameters.

It allows to define the thresholds of auxiliary integration 

intervention  (boiler  /  electric  heater)  to  the  heating 

based on the request (the ability to reach the set point 

in a given time interval) and on its proportional part.

It is defined the working condition to which the heat 

pump requires help from the integration, namely the 

condition of “crisis”.

• 

ON-Request: it represents the request 

generated by PID of the reached water that 

activate the integration. 

• 

ON-Propor.: it represents the distance from 

the  set,  in  percentage,  over  that  activate 

auxiliary integration.

For example: the percentage of the proportional band 

Hc06  as  per  factory  default  is  set  at  10.  The  60%  of 

10 is 6°C . It represents the proportional enabling the 

integration  of  auxliary  heating.  Higher  this  value  is  it 

means the machine is far from set. If this value was low 

and the previous higher, the boiler could start even if it 

isn’t necessary, for example if the machine stayed near 

the set (low proportional) for long time (high integral 

pushing), no reaching it. In qthis case the machine 

would be  a little subsized but it could heat the water 

in  any  case,  without  a  necessary  intervention  of  the 

boiler.

The combination of the two previous parameters, then, 

identifies when the machine is really in crisis and needs 

integration. Happening both conditions the integration 

is active.

• 

OFF-Propor.:  it’s  the  percentage  of  the 

proportional band Hc06, that as defaut is set 

at 10, under that the integration shut down.

• 

OFF-Diff.:  Degrees  the  integration  has  to 

produce more on Setpoint set on the heat 

pump.

Mask Gfc03: 

integration activation in case of need 

(heat pump in “crisis”).

• 

Setpoint act.:   external temperature value 

under that the boiler is enabled to start if the 

machine is considered in crisis ( parameters in 

Gfc02)

• 

Differential: 

deltaT  positive,  that  is 

the  integration  is  enabled  until  the  external 

temperature reaches a temperature equal to 

SDifferential.

• 

Boiler  activation  delay: verify previous 

conditions, the boiler is activated if they stay 

for the time set.

Mask Gfc04: 

integration  activated  according  to 

the outside temperature.

In this case the integration started when the outside air 

temperature falls below the set value. Once activated 

the auxiliary source, it works in conjunction with a heat 

pump, unless it is not been set her to turn off.

Integration remains active until it reaches the set water 

setpoint, although the air temperature rises above the 

value set.

• 

Setpoint  act.: external temperature value 

that  enable  the  heating  control,  heating 

independent from other factors

• 

Differential:  deltaT  positive,  that  is  the 

integration  is  enabled  until  the  external 

temperature reaches a value equal to 

SDifferential.

• 

Turn off compressors: it allows to turn off the 

heat pump under the defined temperature in 

Setpoint  act.  :  the  integrated  system  totally 

replaces the heat pump.

 

 

  Mask Gfc07: riserved

Maschera Gfc15: reset antifreeze alarm.

• 

Reset  antifreeze  alarm  primary  circuit: it 

allows to establish if the rearming is manual 

or automatic. 

• 

Manual: (default) the machine restarts only if 

the user resets resetta manually the alarm.

• 

Auto:  the  machine  restarts  automatically 

when  the  flow  temperature  is  increased  to 

the value Set_alarm_anti Diff._Activat                                

Mask Gfc20: resetting set overheating reset .

• 

Reset  overheat.  alarm  primary  circuit:  it 

permits to establish if the resetting is manual 

or automatic. 

 • 

Manual: (default) the machine restarts only 

if the user resets the alarm manually.

 • 

Auto:  the  machine  restart  automatically 

when the flow temperature  is decreased to 

the value Set_alarm_overheat-Diff._Activat.

Mask  Gfc21:  selection  for  the  setting  of  the  mode 

(winter or summer) through user panel or remore 

external switch (digital).

•  

Summer/Winter  selec.  Season  from: it is 

possible  to  choose  between  “KEYBOARD” 

(operator  panel)  or  “IN.  DIG.  1”  .  In  this 

case you have to consider it isn’t enough to 

manage the commutation summer/winter.

Summary of Contents for KITA AIR

Page 1: ...INSTALLATION INSTRUCTION AIR TO AIR T H E H E A T P U M P...

Page 2: ...ts 8 6 3 Free spaces for the assembly 8 6 4 Choice of installation place 9 6 5 External unit mounting 9 6 6 Condensate discharge preparation 9 6 7 Correct alignment 10 6 8 Probe installation 10 7 Mont...

Page 3: ...8 12 5 Electric diagram KITA AIR 19 12 6 Internal wiring connection diagram 20 13 Commissioning 21 13 1 Preliminary controls 21 13 2 Commissioning 21 14 Control unit 22 14 1 Control panel measurement...

Page 4: ...sary please request for original parts You can find all informations on the KITA Templari label in accordance with the regulation on labeling in particular you can find Voltage and frequency of Power...

Page 5: ...supply For design and realization of the heat pump all the CE directives and all the DIN and VDE have been observed The electric connection of the heat pump must be made in accordance with the VDE EN...

Page 6: ...e indicated on the plate 1 Figure 1 and 2 figure 1 1 3 3 Operation mode The heat pump can operate in two modes actionable trough the switching of the 4 way valve as shown below this modes are heating...

Page 7: ...mension 1 Deflector 2 Fan 3 Case 4 Battery exchanger 5 Electric box 6 Side cover remove to access to electric box 7 Probe cable B2 prewired to unroll The image is intended only to indicate the main in...

Page 8: ...he provisions in force It is recommended to pay attention do not to overexertion when lifting the internal unit It is advisable to be at least in two persons 6 Mounting and installation 6 1 Equipment...

Page 9: ...are snowfalls install the heat pump at least 25 cm from the ground to avoid clogging at the inlet and drain zone 6 5 External unit mounting 1 Before installing the device please see the safety warnin...

Page 10: ...e irreparable damages to the evaporator In places where there are snowfalls install the heat pump at least 25 cm from the floor to avoid clogging in the suction and condensate drain area 6 7 Correct a...

Page 11: ...the circuit Nominal lenght Maximum lenght of the piping m of equivalent length Maximum height difference m of equivalent length Additional refrigerant charge recommended g m of equivalent length All...

Page 12: ...connect the pump charging vacuum connection procedure 1 4 inside the external unit Perform the vacuum until reaching 0 4mbr pressure duration of procedure for about 1 h for 15m total length connection...

Page 13: ...or incrustations of various kinds also provoking a malfunctioning of the heat pump It is possible then clean the battery with a under pressure jet of air in a parallel direction of the fins you should...

Page 14: ...cable The cable carries low voltage control signals find a route far from sources of interference do not joints along the way possibly using a 3 core cable shield section 1 50 sq mm shield connected...

Page 15: ...ower supply cables indication KITA AIR External unit Supply 400 Vac 50 Hz Cable 5x6 mmq Secondary line protection 230 PC protection 24 Vdc 3 fuses 5x20 4A 1 fuse 5x20 4A Internal unit Supply 230 Vac 5...

Page 16: ...E 1 3 5 7 9 11 2 4 6 8 10 12 B2 1 3 5 7 9 11 2 4 6 8 10 12 B2 Gnd B4 GND B5 VDC B3 GND Y3 GND B7 GND C 230V auxiliary power supply internal fan A Auxiliary fuses 4 A B Power Phase Neutal and Ground fo...

Page 17: ...switch high DI6 solar boost SGR bit0 DI8 remote on off DI9 P Lan protocol DI10 flow switch present on old models F4 Elektrische Sicherung 5x20 250 mA Y2 Y3 PWM Circulator GND 5VR C4 NO8 NO9 NO10 NO11...

Page 18: ...alve 14 Block outputs C1 NO1 NO3 15 Block outputs C2 NO4 NO6 16 Block outputs C3 No7 Nc7 17 Block outputs C4 NO8 NO12 18 Bar hooks Din 35 6 1 2 3 4 5 9 7 8 17 10 11 12 13 14 15 16 18 18 18 12 1 Digita...

Page 19: ...IDC2 J8 J10 J12 J13 J14 J15 J1 5 J 4 J 3 J 2 J J18 J16 R S T N R S T N N EVV EVV M OUT 5vrf M OUT 5vrf R S T Heater condensate drain Injection valve 4 4 CH 3 RS485 M 3 M 3 RS485 Bridge to the terminal...

Page 20: ...2 1 N Lok 6 Yellow Green N Blue T Brown N Blue N Blue NO11 6 5 4 3 2 1 N Lok 9 Brown PE Yellow Green No10 Brown 8 7 9 20 19 B6 B1 14 13 12 11 10 9 Molex Mini Fit Jr 20 White 5V Red Gnd Black B11 B10 W...

Page 21: ...y the proper operation Access to menu D inputs outputs to control the different temperatures from sensors Screen D01 B1 it shows the value of liquid sub cooling in the heat pump it has to stay in a ra...

Page 22: ...ivation It activates when the solar panels are installed and active It activates when the defrosting procedure is active 4 Unit status The unit can be in one of the following states OFF ON ENERGY S AU...

Page 23: ...20 percentage points Those conditions permit to work with a noisiness more and more reduced We underline that setting this function the efficiency of the machine too is progressively reduced Mask B06...

Page 24: ...the other days press and proceed as explained above Contrary it is possible to copy the setting in different days once entered in mask C02 press the button to have access to the choice of the day you...

Page 25: ...ating DSH Discharge Super Heating Mask D19 Parameters Inverter Engine Mask D20 Parameters Inverter Engine Mask D21 Parameters Inverter Engine Masks D30 D31 masks relevant to the external battery fan Y...

Page 26: ...ion is active OFF Propor it s the percentage of the proportional band Hc06 that as defaut is set at 10 under that the integration shut down OFF Diff Degrees the integration has to produce more on Setp...

Page 27: ...the defrosting is finished because the maximum time is exceeded Mask Gfc50 It allows to enable the condensate drain in fix or intermittent mode in base on the external temperature Res drain cond it e...

Page 28: ...bles speed manual management of compressor for the heat pump in heating and cooling speed if the manual management is active it shows the compressor speed for the heat pump Mask Gg06 it enables the de...

Page 29: ...ors D06 Analog sensors D07 Fan speed Circulator speed D08 Cooling circuit status D09 Work regime D10 Work pressures D11 Work pressures D14 Drain Gas Control D15 EED set up D19 Inverter Engine paramete...

Page 30: ...A12 Probe B12 broken or disconnected Automatic 60 sec Yes Stop the machine ALB01 Position ID3 High pressure Manual Immediate Yes Stop the machine ALB02 High pressure of the compressor 1 from transduce...

Page 31: ...e Immediate Settable Gfa01 Only signal ALT08 Threshold reached worked hours outside battery fan Manual Immediate Settable Gfa01 Only signal ALU01 Geothermal frosting protection exchanger Manual par Gf...

Page 32: ...of time the cause can be the inertia of the system and the nearness between the temperatures of air and water If it occurs occasionally it s just a no serious signal permitting to the unit to keep on...

Page 33: ...umer 1 Nominal diameter mm 910 Maximum input power kW 0 625 Maximum current A 1 1 Max speed rps 610 Max air flow m3 h 15000 Internal fan Model EBMPAPST Type Inverter BLDC Numer 1 Nominal diameter mm 8...

Page 34: ...ate Applied standard Standard Armonizzati EN 55014 1 2006 A1 2009 EN 55014 2 1997 A 2001 A2 2008 EN 61000 3 2 2006 A1 A2 2009 EN 61000 4 2 2008 61000 4 4 2008 EN 61000 4 5 2008 EN 61000 4 6 2008 Angew...

Page 35: ...Note...

Page 36: ...vers 26 07 2019 C via Pitagora 20A 35030 Rubano PD Italia Tel 39 049 8597400 39 049 5225929 www templari com info templari com T H E H E A T P U M P...

Reviews: