Band Annealing Pressure Point
(Jaw Level Calibration)
Clamping Pressure should be correct for each selected band-width.
When Clamping Jaws are on annealing position and using the annealing procedure the heat
will show where the Annealing Press Point are.
Where the pressure is, there is the electric connectivity higher, so the heat we want to create
for proper annealing is there as highest. The goal is to create similar heat on all width of Metal-Band
at the same time
like on picture # 1.
Picture # 1
Picture # 2
Improper Adjustment
LOWER JAW
UPPER JAW
METAL BAND
PRESS POINT
HEAT AREA
LOWER JAW
METAL BAND
PRESS POINT
HEAT AREA