137
19.1
Specifications
Supply voltage, DC V
10...50*
Current consumption, mA (for 12/24 V)
25/50
Operation temperature, Celsius degrees
-40...+85
Working mode
continuous
Weight, kg
< 2.0
Working pressure
atmospheric
19.2
Hardware
Operation principle: capacitive.
Output: RS-232 or RS-485.
Standard probe lengths: 700, 1000, 1500 mm.
Optocoupler isolation on both power and signal circuits.
Omnicom LLS wires colors and description:
Output number
Interface
Wire purpose
C1
Brown
Power supply «+»
C2
White
Ground «-»
B1
Pink
RS-232 “TX”
B2
Grey
RS-232 “RX”
A1
Orange-White
EIA-485 “Line A”
A2
Blue-white
EIA-485 “Line B”
19.3
Connecting LLS to FM5500
In order to use LLS fuel counter the 01.00.01 Firmware version or later is needed which can
be obtained from Teltonika or a representative. Firmware is updated by using cable update
method (see chapter 4 for more information).
The LLS fuel sensor can be connected to the FM5500 device via RS232 or RS485 interface.
Port 1 has both RS485 and RS232 interface.When LLS is connected via RS485, RS232 line can be
used for other purposes. Port 2 can use only RS-232 protocol. The FM5500-LLS fuel sensor
connection schemes are shown below.
*Teltonika is not responsible for any changes made by the manufacturer, which is not declared in fuel level
sensor documentation.
Port on FM55 side.